• Anesthesia and analgesia · Apr 2012

    Determination of vascular waterfall phenomenon by bedside measurement of mean systemic filling pressure and critical closing pressure in the intensive care unit.

    • Jacinta J Maas, Rob B de Wilde, Leon P Aarts, Michael R Pinsky, and Jos R Jansen.
    • Department of Intensive Care, B4, Leiden University Medical Center, P.O.B. 9600, 2300 RC Leiden, The Netherlands. j.j.maas@lumc.nl
    • Anesth. Analg.. 2012 Apr 1;114(4):803-10.

    BackgroundMean systemic filling pressure (Pmsf) can be determined at the bedside by measuring central venous pressure (Pcv) and cardiac output (CO) during inspiratory hold maneuvers. Critical closing pressure (Pcc) can be determined using the same method measuring arterial pressure (Pa) and CO. If Pcc > Pmsf, there is then a vascular waterfall. In this study, we assessed the existence of a waterfall and its implications for the calculation of vascular resistances by determining Pmsf and Pcc at the bedside.MethodsIn 10 mechanically ventilated postcardiac surgery patients, inspiratory hold maneuvers were performed, transiently increasing Pcv and decreasing Pa and CO to 4 different steady-state levels. For each patient, values of Pcv and CO were plotted in a venous return curve to determine Pmsf. Similarly, Pcc was determined with a ventricular output curve plotted for Pa and CO. Measurements were performed in each patient before and after volume expansion with 0.5 L colloid, and vascular resistances were calculated.ResultsFor every patient, the relationship between the 4 measurements of Pcv and CO and of Pa and CO was linear. Baseline Pmsf was 18.7 ± 4.0 mm Hg (mean ± SD) and differed significantly from Pcc 45.5 ± 11.1 mm Hg (P < 0.0001). The difference of Pcc and Pmsf was 26.8 ± 10.7 mm Hg, indicating the presence of a systemic vascular waterfall. Volume expansion increased Pmsf (26.3 ± 3.2 mm Hg), Pcc (51.5 ± 9.0 mm Hg), and CO (5.5 ± 1.8 to 6.8 ± 1.8 L · min(-1)). Arterial (upstream of Pcc) and venous (downstream of Pmsf) vascular resistance were 8.27 ± 4.45 and 2.75 ± 1.23 mm Hg · min · L(-1); the sum of both (11.01 mm Hg · min · L(-1)) was significantly different from total systemic vascular resistance (16.56 ± 8.57 mm Hg · min · L(-1); P = 0.005). Arterial resistance was related to total resistance.ConclusionsVascular pressure gradients in cardiac surgery patients suggest the presence of a vascular waterfall phenomenon, which is not affected by CO. Thus, measures of total systemic vascular resistance may become irrelevant in assessing systemic vasomotor tone.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…