• Anesthesia and analgesia · Jun 2000

    Randomized Controlled Trial Clinical Trial

    The assessment of dermatomal level of surgical anesthesia after spinal tetracaine.

    • S Sakura, Y Sakaguchi, M Shinzawa, K Hara, and Y Saito.
    • Department of Anesthesiology, Shimane Medical University, Izumo City, Japan. ssakura@shimane-med.ac.jp
    • Anesth. Analg. 2000 Jun 1;90(6):1406-10.

    UnlabelledTranscutaneous electrical stimulation (TES), a 60-mA, 50-Hz continuous square wave, has been considered equivalent to surgical incision. We examined whether TES at a smaller current (10 mA) can be used to predict surgical anesthesia and compare the results with sensory block to cold, pinprick, and touch after the administration of spinal tetracaine. Two groups of 40 consecutive patients, 17-69 yr old and 70 yr old or older received a subarachnoid injection of 0. 5% tetracaine in 10% glucose or saline according to the type of surgery. Patients undergoing abdominal surgery received glucose solution, and those scheduled for lower extremities surgery received saline solution, and thus, the resultant four groups of patients were studied. Neural block was assessed by the loss of sensation to cold, pinprick, touch, and TES at 10 mA (T10s), and tolerance (i.e., the loss of pain or discomfort) to TES at 10 (T10p) and 60 (T60) mA. Dermatomal levels of sensory block to cold, pinprick, and touch that were cephalad to T60 varied widely. In contrast, dermatomal levels of T10s and T10p cephalad to T60 were less variable, and the difference between T10s and T60 was the smallest among all the differences in any groups. Our results demonstrate that, regardless of patient age and baricity of a local anesthetic solution, T10s is a good predictor of T60 equivalent to the dermatomal level of surgical anesthesia.ImplicationsOur results show that the loss of sensation to transcutaneous electrical stimulation at 10 mA, but not cold, pinprick, or touch, is a good predictor of the dermatomal level of block to transcutaneous electrical stimulation at 60 mA, which is considered equivalent to the dermatomal level of surgical anesthesia after the administration of spinal anesthesia.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…