• Chest · Mar 2014

    Performance comparisons of jet and mesh nebulizers with mouthpiece, aerosol mask, and valved mask in simulated spontaneously breathing adults.

    • Arzu Ari.
    • Chest. 2014 Mar 1;145(3 Suppl):548A.

    Session TitleRespiratory Support PostersSESSION TYPE: Poster PresentationsPRESENTED ON: Saturday, March 22, 2014 at 01:15 PM - 02:15 PMPURPOSE: A variety of nebulizers and interfaces are used to administer medical aerosols to adults with pulmonary diseases. The purpose of this study was to determine the efficiency of a mesh nebulizer (MN) with adaptor and jet nebulizer (JN) using mouthpiece, valved-mask and open aerosol mask during simulated adult breathing parameters.MethodsA teaching manikin connected to a sinusoidal pump simulating spontaneous adult breathing (Vt 500 mL, RR 15 bpm and I:E ratio 1:2) via a collecting filter distal to bronchi. Albuterol sulfate (2.5 mg/3 mL) was aerosolized with JN (Mistymax 10, Airlife) and MN with a prototype adaptor (Aeroneb Solo, Aerogen Ltd, Galway, Ireland) using mouthpiece, open aerosol mask, and valved-mask (n=3). The valved-mask was a modified non-rebreathing oxygen mask with one-way valves on ports on both sides of the mask. The JN was operated at 10 L/min while the MN with adapter was used with supplemental oxygen of 2 lpm. Drug was eluted from the filter and analyzed via spectrophotometry. Descriptive statistics and ANOVA were used (p<0.05).ResultsThe percent of dose deposited distal to the bronchi (mean ± SD) with the JN was greater with the valved-mask (8.63 ± 0.22) and mouthpiece (7.66 ± 0.62) than open aerosol mask (6.84 ± 0.49). When supplemental oxygen of 2 lpm was used with MN, aerosol deposition with MN was similar with mouthpiece and valved-mask (15.42 ± 1.41 and 15.15 ± 1.05, respectively), but 50% lower with the open aerosol mask (7.54 ± 0.39; p=0.0001). Delivery efficiency of MN was two-fold more than JN with mouthpiece or valved-mask (p=0.01 and p=0.01, respectively). Without supplemental oxygen, MN with mouthpiece achieved up to 30% inhaled mass.ConclusionsThe MN with adapter was more efficient than JN with both mouthpiece and valved-mask, while the open aerosol mask was delivered the least drug independent of nebulizer used in this study.Clinical ImplicationsSelection of nebulizer and interface for aerosol therapy has a large impact on the amount of drug inhaled.DisclosureJames Fink: Consultant fee, speaker bureau, advisory committee, etc.: Bayer, Boerhinger Ingleheim, Cubist, Dance Biopharm, Novartis, ONY, Parion, Aridis, and the WHO The following authors have nothing to disclose: Arzu Ari, Armele Dornelas de AndradeNo Product/Research Disclosure Information.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…