• Chest · Mar 2014

    Pocket pulse oximetry versus standard pulse oximetry: accuracy and precision.

    • João Cordeiro da Costa, Ana Roque, Paula Faustino, Filipa Viveiros, and Miguel Guimarães.
    • Chest. 2014 Mar 1;145(3 Suppl):549A.

    Session TitleRespiratory Support PostersSESSION TYPE: Poster PresentationsPRESENTED ON: Saturday, March 22, 2014 at 01:15 PM - 02:15 PMPURPOSE: Pulse oximetry is nowadays a disseminated technology available almost over the corner. "Pocket" pulse oximeters are now widely available and knowing its precision and accuracy is of great importance in clinical practice.MethodsCross-sectional study. Inclusion criteria: Patients older than 18, performing blood gas analysis from 1 July to 31 August 2013 on Lung Function Laboratory of our Hospital; Exclusion criteria: patients undergoing home oxygen-therapy. A protocol was created in which all enrolled patients had SPO2 simultaneously measured by "pocket" (Riester Ri-Fox) and "standard" (Respironics 920M Plus, Nonin finger sensor) high quality pulse oximetry; blood gas analysis was performed with correction to temperature; blood pressure and cardiac frequency were measured to exclude important hypoperfusion. Statistical analysis: continuous variables were presented by means and standard deviations (normal distribution); T Test and Bland and Altman Technique were performed. Statistical significance was set to α<0.05. Data were collected using CDC EpiInfo version 7 and analyzed using IBM SPSS version 22.ResultsNinety-five patients were enrolled (35.8% women); mean age was 63.1 years; mean arterial pressure was 92 mmHg (SD 12.0) and mean heart rate was 78 (SD 13.8). T test showed no statistical difference between pulse oximeters (mean difference [SPO2 Standard - SPO2 Pocket] = 0.01, SE 0.20, p=0.958). Both pocket and standard oximeters were statistically different from co-oximetry oxihemoglobin (p<0.001 CI 95% [-1.78 to -0.61] and p<0.001 CI 95% [-1.58 to -0.74] respectively) and from SaO2 (p<0.001 CI 95% [1.40 to 2.30] and p<0.001 CI 95% [1.49 to 2.19], respectively), although less than 2%.ConclusionsBoth pocket and standard high quality oximeter performed similarly and both were discordant of oxihemoglobin (lower than pulse oximetry) and SaO2 (higher than pulse oximetry). The mean differences were below 2%, so without great clinical significance.Clinical ImplicationsCheaper and affordable new pocket pulse oximeters can be of great value in clinical practice and in ambulatory patient monitoring.DisclosureThe following authors have nothing to disclose: João Cordeiro da Costa, Ana Roque, Paula Faustino, Ricardo Lima, Filipa Viveiros, Miguel GuimarãesNo Product/Research Disclosure Information.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.