- João Cordeiro da Costa, Ana Roque, Paula Faustino, Filipa Viveiros, and Miguel Guimarães.
- Chest. 2014 Mar 1;145(3 Suppl):549A.
Session TitleRespiratory Support PostersSESSION TYPE: Poster PresentationsPRESENTED ON: Saturday, March 22, 2014 at 01:15 PM - 02:15 PMPURPOSE: Pulse oximetry is nowadays a disseminated technology available almost over the corner. "Pocket" pulse oximeters are now widely available and knowing its precision and accuracy is of great importance in clinical practice.MethodsCross-sectional study. Inclusion criteria: Patients older than 18, performing blood gas analysis from 1 July to 31 August 2013 on Lung Function Laboratory of our Hospital; Exclusion criteria: patients undergoing home oxygen-therapy. A protocol was created in which all enrolled patients had SPO2 simultaneously measured by "pocket" (Riester Ri-Fox) and "standard" (Respironics 920M Plus, Nonin finger sensor) high quality pulse oximetry; blood gas analysis was performed with correction to temperature; blood pressure and cardiac frequency were measured to exclude important hypoperfusion. Statistical analysis: continuous variables were presented by means and standard deviations (normal distribution); T Test and Bland and Altman Technique were performed. Statistical significance was set to α<0.05. Data were collected using CDC EpiInfo version 7 and analyzed using IBM SPSS version 22.ResultsNinety-five patients were enrolled (35.8% women); mean age was 63.1 years; mean arterial pressure was 92 mmHg (SD 12.0) and mean heart rate was 78 (SD 13.8). T test showed no statistical difference between pulse oximeters (mean difference [SPO2 Standard - SPO2 Pocket] = 0.01, SE 0.20, p=0.958). Both pocket and standard oximeters were statistically different from co-oximetry oxihemoglobin (p<0.001 CI 95% [-1.78 to -0.61] and p<0.001 CI 95% [-1.58 to -0.74] respectively) and from SaO2 (p<0.001 CI 95% [1.40 to 2.30] and p<0.001 CI 95% [1.49 to 2.19], respectively), although less than 2%.ConclusionsBoth pocket and standard high quality oximeter performed similarly and both were discordant of oxihemoglobin (lower than pulse oximetry) and SaO2 (higher than pulse oximetry). The mean differences were below 2%, so without great clinical significance.Clinical ImplicationsCheaper and affordable new pocket pulse oximeters can be of great value in clinical practice and in ambulatory patient monitoring.DisclosureThe following authors have nothing to disclose: João Cordeiro da Costa, Ana Roque, Paula Faustino, Ricardo Lima, Filipa Viveiros, Miguel GuimarãesNo Product/Research Disclosure Information.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.