-
AJR Am J Roentgenol · Mar 2004
Comparative StudyMDCT evaluation of thoracic aortic anomalies in pediatric patients and young adults: comparison of axial, multiplanar, and 3D images.
- Edward Y Lee, Marilyn J Siegel, Charles F Hildebolt, Fernando R Gutierrez, Sanjeev Bhalla, and Juliet H Fallah.
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd., St. Louis, MO 63110, USA.
- AJR Am J Roentgenol. 2004 Mar 1;182(3):777-84.
ObjectiveThe objective of our study was to compare accuracies of axial, multiplanar, and 3D volume-rendered images in the diagnosis of thoracic aortic anomalies in pediatric patients and young adults.Materials And MethodsFourteen patients, 17 days to 20 years old, with thoracic aortic anomalies underwent MDCT using axial, multiplanar, and 3D volume-rendering imaging. All images were reviewed by three radiologists for position of the aortic arch, coarctation, vascular compression of the airway, collateral vessel formation, and aortopulmonary shunts (patent ductus arteriosus). Final diagnosis was determined by echocardiography, conventional angiography, bronchoscopy, or surgery. Diagnostic accuracy, sensitivity, and interobserver agreement were evaluated.ResultsAverage accuracies (average of the three observers for a correct diagnosis) were greater than or equal to 96% for diagnoses of aortic position and airway narrowing on all image types. For the diagnosis of coarctation, average sensitivities (average of the three observers for a true diagnosis) were 73% for axial, 100% for multiplanar, and 100% for 3D volume-rendered images. For the diagnosis of patent ductus arteriosus, average sensitivities were 78% for axial, 94% for multiplanar, and 89% for 3D volume-rendered images. No patients in this study had collateral vessel formation. For the diagnosis of absence of collateral vessel formation, average sensitivities were 100% for axial, 100% for multiplanar, and 100% for 3D volume-rendered images. There were no significant statistical differences in diagnostic performances, agreement with truth, or confidence scores among observers or imaging formats (p > 0.05).ConclusionAxial, multiplanar, and 3D volume-rendered images serve equally well as methods for assessing the side of the aorta to diagnose anomalies. For evaluation of coarctation and patent ductus arteriosus, multiplanar and 3D volume-rendered images perform slightly better than axial images.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.