• J Trauma Acute Care Surg · Jul 2015

    Portable mechanical ventilation with closed-loop control of inspired fraction of oxygen maintains oxygenation in the setting of hemorrhage and lung injury.

    • Peter L Jernigan, Richard S Hoehn, Thomas C Blakeman, Judy Heyl, Bryce R H Robinson, Timothy A Pritts, and Richard D Branson.
    • From the Division of Trauma and Critical Care, Department of Surgery, Institute for Military Medicine, University of Cincinnati College of Medicine, Cincinnati, Ohio.
    • J Trauma Acute Care Surg. 2015 Jul 1;79(1):53-9; discussion 59.

    BackgroundClosed-loop controllers (CLCs) embedded within portable mechanical ventilators may allow for autonomous weaning. The ability of CLCs to maintain adequate oxygenation in the setting of hemorrhage and lung injury is unknown. We hypothesized that a portable ventilator with a CLC for inspired fraction of oxygen (FIO2) could provide oxygenation in a porcine model of hemorrhage and lung injury.MethodsFemale pigs randomized to the study group (n = 6) underwent a pressure-controlled bleed (mean arterial pressure = 40 mm Hg for 30 minutes). Acute lung injury was induced by saline lung lavage followed by intentional infliction of barotrauma. Sham pigs (n = 6) underwent placement of monitoring devices without hemorrhage or lung injury. All pigs were then placed on a portable ventilator modified with a CLC algorithm, which uses feedback from pulse oximetry (SpO2) and FIO2 trends to adjust FIO2 and maintain a target SpO2 of 94% (2%). The initial FIO2 was set at 0.60. Tidal volume, positive end-expiratory pressure, rate, and inspiratory-to-expiratory ratio were constant unless changes were required clinically.ResultsStudy pigs had lower mean arterial pressures than shams at all time points except baseline. PaO2/FIO2 ratios were less than 300 and significantly lower than both baseline values and corresponding sham values at all time points. The CLC weaned the FIO2 at a reduced rate in study pigs relative to shams with a final mean FIO2 of 0.54 and 0.29 in study and sham pigs, respectively (p < 0.05). There was a significant divergence in the study and sham FIO2 curves but no significant difference in oxygen saturation or hypoxemia.ConclusionAdequate oxygenation can be maintained in the setting of hemorrhage and lung injury using a portable ventilator embedded with a CLC of FIO2 based on pulse oximetry. These devices may be valuable for providing advanced medical care in resource-limited environments.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.