• Yale J Biol Med · Jan 1998

    Case Reports

    Pulmonary atresia with ventricular septal defect: a case for central venous pressure and oxygen saturation monitoring.

    • B M Weiss, P G Atanassoff, R Jenni, B Walder, and E Wight.
    • Department of Anesthesiology, University Hospital, Zurich, Switzerland.
    • Yale J Biol Med. 1998 Jan 1;71(1):15-21.

    AbstractA 21-year-old patient with pulmonary atresia and ventricular septal defect (PA-VSD) was admitted to the hospital for tubal ligation. Invasive arterial and central venous (CVP) pressure, pulse oximetric oxygen saturation (SpO2), and (from the tip of oximetric central venous catheter) central venous oxygen saturation (ScvO2) and oxygen extraction rate (ExO2) were continuously monitored. Heart rate (range: 68-75 beat/min), mean arterial pressure (80-90 mmHg), CVP (7-10 mmHg), SpO2 (79-90 percent), ScvO2 (57-70 percent), and ExO2 (21-30 percent) remained stable during epidural anesthesia and transvaginal sterilization. Following an overnight stay (peak SpO2 92 percent; peak ScvO2 71 percent; through ExO2 21 percent), the oxygen data returned to baseline on awakening (SpO2 < 80 percent, ScvO2 < 55 percent, ExO2 > 35 percent), and the patient was discharged. In PA-VSD, a single-outlet double-ventricle anomaly, CVP reflects the preload of systemic ventricle. As the mixed venous oxygen saturation cannot be defined, ScvO2 is the best available indicator of the whole body oxygen consumption. Continuous monitoring of CVP, ScvO2 and ExO2 in the superior vena cava may provide more insight into the response to anesthesia and surgery in patients with PA-VSD.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…