A 21-year-old patient with pulmonary atresia and ventricular septal defect (PA-VSD) was admitted to the hospital for tubal ligation. Invasive arterial and central venous (CVP) pressure, pulse oximetric oxygen saturation (SpO2), and (from the tip of oximetric central venous catheter) central venous oxygen saturation (ScvO2) and oxygen extraction rate (ExO2) were continuously monitored. Heart rate (range: 68-75 beat/min), mean arterial pressure (80-90 mmHg), CVP (7-10 mmHg), SpO2 (79-90 percent), ScvO2 (57-70 percent), and ExO2 (21-30 percent) remained stable during epidural anesthesia and transvaginal sterilization. ⋯ In PA-VSD, a single-outlet double-ventricle anomaly, CVP reflects the preload of systemic ventricle. As the mixed venous oxygen saturation cannot be defined, ScvO2 is the best available indicator of the whole body oxygen consumption. Continuous monitoring of CVP, ScvO2 and ExO2 in the superior vena cava may provide more insight into the response to anesthesia and surgery in patients with PA-VSD.