Clin Neurol Neurosurg · Oct 2014
Accuracy of C2 pedicle screw placement using the anatomic freehand technique.
- Mohamad Bydon, Dimitrios Mathios, Mohamed Macki, Rafael De la Garza-Ramos, Nafi Aygun, Daniel M Sciubba, Timothy F Witham, Ziya L Gokaslan, Ali Bydon, and Jean-Paul Wolinksy.
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, USA; Johns Hopkins Spinal Biomechanics and Surgical Outcomes Laboratory, Baltimore, USA. Electronic address: mbydon1@jhmi.edu.
- Clin Neurol Neurosurg. 2014 Oct 1;125:24-7.
ObjectiveThe objective of this study is to evaluate the incidence and prognostic factors of breach rates following the placement of C2 pedicle screws using the anatomic, freehand technique.MethodsWe retrospectively reviewed the medical records of all patients who underwent C2 transpedicular instrumentation over six years at a single institution. All intraoperative, image-guided techniques were excluded. Breaches were ascertained from immediate postoperative CT images. All images were analyzed by three independent reviewers. The screw length was correlated with (1) the breach rate and (2) the breach severity. Severity of the breached screws reflects the screw circumference (0-360°) perforating the pedicle wall (Grade 1-Grade 4).ResultsOf the 341 C2 pedicle screws inserted in 181 patients, the average screw length was 22.93±3.7mm. The average distance from the foramen transversarium to the screw insertion point was 13.17±2.63mm. The distance from the medial rim of the pedicle to the dura of spinal cord was 3.53±1.57mm. Of the 341 screws, the overall breach rate was 17.3% (n=59). Of the 59 breaches, 89.83% of screws (n=53) breaching the spinal canal was statistically significantly higher than the 10.17% of screws (n=6) breaching the foramen transversarium (p<0.001). Moreover, 27 (45.8%) were Grade 1, 16 (27.1%) Grade 2, 6 (10.2%) Grade 3, and 10 (16.9%) Grade 4. None of the C2 breaches resulted in neurological sequela. No association was found between breach rate and gender, race or age. While the average screw length was 22.93±3.7mm [12-34mm], screw length did not predict a cortical violation (p=0.4) or severity of the breach (p=0.42) in a multiple regression model.ConclusionsIn this cohort study on the anatomic freehand placement of C2 pedicle screws, the breach rate was 17.3%. Lateral breaches were more common than medial breaches. Screw length was not statistically correlated with cortical violation or severity of breach. Therefore, screw length is not a prognostic factor for C2 pedicle screw misplacement.Copyright © 2014 Elsevier B.V. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.