• J Extra Corpor Technol · Mar 2004

    North American neonatal extracorporeal membrane oxygenation (ECMO) devices: 2002 survey results.

    • D Scott Lawson, Rich Walczak, Andrea F Lawson, Ian R Shearer, Richard Ing, Scott Schulman, Frank Kern, and James Jaggers.
    • Duke University Health System, Durham, North Carolina 27710, USA. lawso008@mc.duke.edu
    • J Extra Corpor Technol. 2004 Mar 1;36(1):16-21.

    AbstractIn mid 2002, surveys of active extracorporeal membrane oxygenation (ECMO) centers in the United States and Canada were conducted via E-mail regarding neonatal equipment and personnel. Seventy-four out of 99 (75%) North American ECMO centers listed in the Extracorporeal Life Support Organization (ELSO) directory responded to the survey. Of the responding centers, 95% use roller pumps, and the remaining 5% use centrifugal pumps. Silicone membrane oxygenators were used by 97% of the respondents, while 3% used hollow fiber oxygenators. Of the silicone membrane oxygenator users, 82% used the Medtronic ECMOtherm heat exchanger, 15% used a Gish heat exchanger, and 3% used the Dideco D720 heat exchanger. Sixty-one percent of the responding centers used some form of in-line blood gas monitoring. Five percent of the centers used a bubble trap in the arterial line, and 12% used an arterial line filter. A bladder was used by 92% of the centers, and 29% used a mechanical bladder box for servo regulation, the remaining 71% used pressure servo regulation. An air bubble detector was used by 65% of the responding centers, although 81% had the device available. Heparin coating was used by 5% of the centers on all their neonatal ECMO patients. The average low range ACT was 183 seconds, and the average high range ACT was 216 seconds. At 49% of the responding centers, perfusionists were involved with the ECMO program, registered nurses were involved at 84% of the centers, and respiratory therapists were involved at 61% of the centers, perfusion assistants were involved at one center (1%), and biomedical engineers were involved at one of the centers. When compared to a 1990 survey, a shift away from using bladder boxes and toward using air bubble detectors is apparent. But other than those two shifts, ECMO is done in much the same manner as it was done 12 years ago.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…