• Lasers Surg Med · Mar 2015

    Assessment of irrigation dynamics in magnetic-resonance guided laser induced thermal therapy (MRgLITT).

    • Saurabh Sinha, Eric Hargreaves, Nitesh V Patel, and Shabbar F Danish.
    • Division of Neurosurgery, Rutgers Robert Wood Johnson Medical School, New Brunswick, New Jersey.
    • Lasers Surg Med. 2015 Mar 1;47(3):273-80.

    Background And ObjectivesMagnetic-Resonance Guided Laser-Induced Thermal Therapy (MRgLITT) is a minimally-invasive ablation procedure for treating intracranial pathology using laser energy delivered through a fiber-optic. Saline irrigation is used to cool the fiber-optic, but factors affecting irrigation efficacy are not well studied, and quantitative information regarding irrigation speed and volume during MRgLITT procedures have not been reported. Here, we aimed to characterize variables affecting irrigation efficacy in MRgLITT.MethodsWe investigated the irrigation setup of the Visualase thermal therapy system during MRgLITT procedures (Visualase Inc., Houston, TX). Using the system's peristaltic pump, irrigation flow rate was quantitated by measuring volume over five one-minute intervals. Pump settings 1-10 were assessed with and without the position-locking, resistance-imparting bone anchor in both single and double-catheter setups. Multiple tightness settings of the bone anchor were tested, and flow rates were analyzed.ResultsRate of flow increased non-linearly with pump setting (F(1,4) = 2168.86; P < 0.001) in both single and double catheter setups. The lowest pump setting had a flow rate of 24 cc/min, while the highest setting was 36 cc/min. The rate of change in flow successively decreased without plateau. Tightness setting of the bone anchor affected flow in a reverse sigmoid pattern, with no impact on rate until after two quarter-turns, which produced a marked decrease in flow up to one-half of the initial rate (F(1,4) = 12818.96; P < 0.001).ConclusionFlow rate through the cooling catheter in MRgLITT follows a non-linear pattern with increasing peristaltic pump speed. This rate is subject to significant changes when the bone anchor is tightened more than two quarter-turns. These findings serve as a foundation for future studies aimed at understanding the effect of irrigation speeds in achieving optimal ablation volumes.© 2015 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…