• Resuscitation · Dec 2006

    Comparative Study

    Clinical testing of cellular phone ringing interference with automated external defibrillators.

    • Alexandre Trigano, Olivier Blandeau, Christian Dale, Man-Faï Wong, and Joe Wiart.
    • Department of Cardiology, Assistance Publique-Hôpitaux de Marseille, Hôpital Nord, 13915 Marseille, France. alexandre.trigano@mail.ap-hm.fr
    • Resuscitation. 2006 Dec 1;71(3):391-4.

    ObjectiveThis study examined cellular phone ringing interference with automated external defibrillators (AED).MethodsThe phone systems tested were two single band handheld telephones: (1) a Global System for Mobile Communication (GSM) receiver; and (2) a Personal Communication Services (PCS) receiver. The ringing phase of a digital cellular phone includes a brief burst of peak-emitted power. The GSM had a maximum power output of 2 W, operating on a 900 MHz carrier frequency, and the PCS had a maximum output of 1 W, operating on a 1800 MHz carrier frequency. During AED monitoring, the digital cellular telephone was placed successively in three positions: (1) on the AED; (2) on the patient's chest between the electrodes; and (3) on the connector between the electrodes and the AED cable. After positioning the cellular phone, calls were placed during the AED analyzing phase.ResultsThree AED models were tested using their original electrodes: (1) LifePak 20 monitor/defibrillator device; (2) Lifepak 20 P monitor/defibrillator/stimulator (Medtronic Emergency Response Systems, Redmond, WA, USA); and (3) HeartStart XL M4735A monitor/defibrillator (Philips Medical Systems, Andover, MA, USA). The first two devices had Quik-Combo electrodes and the third device had Adults Plus multifunction electrodes. Ninety-one tests were performed on 13 patients. The only disturbance provoked by testing was noise emitted by the AED speaker when the receiver was close to the device. The noise began 2-4 s before the first audible ringing tone and persisted throughout the ringing phase. The distance at which this effect could be prevented was 15 cm.ConclusionClinical testing during ECG monitoring by an AED during call from a cellular phone did not show any analysis dysfunction during unshockable rhythms and provoked only transient dysfunction of the speaker device.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…