• Ann Fr Anesth Reanim · Nov 1999

    Review

    [Anesthesia equipment: fresh gas delivery systems. I. Mecanical systems with rotameters and calibrated vaporizers].

    • J C Otteni, J Ancellin, J B Cazalaà, and P Feiss.
    • Service d'anesthésie-réanimation chirurgicale, hôpitaux universitaires de Strasbourg, France.
    • Ann Fr Anesth Reanim. 1999 Nov 1;18(9):956-75.

    ObjectivesTo analyse the design, performance, failures, the checking before use of mechanical fresh gas delivery units (FGDUs) equipped with bobbin or ball-flowmeters delivering a continuous gas flow and calibrated vaporizers, marketed in France in 1999.Data SourcesArticles were obtained from a Medline review (1960-1999; search terms: anaesthetic machine, flowmeter, vaporizer), textbooks and personal files; specific data were provided by manufacturers.Study Selection And Data ExtractionThe articles were considered for performance data, benefits and drawbacks, and characteristics, as well as the risks carried by mechanical FGDUs.Data SynthesisSeven anaesthetic machines out of 11 are equipped with mechanical FGDUs, including rotameters delivering a gas mixture up to 30 L.min-1, calibrated vaporizers and an O2-flush valve delivering at least 500 mL O2 per second (30 L.min-1). These units allow closed circuit anaesthesia. They carry a risk for barotrauma as three out of them can deliver at the gas outlet of the FGDUs a gas mixture at a pressure reaching 3.5 bars and four others at a pressure of 150-200 mmHg. They also carry a risk for hypoxia, either from a preferential leak of oxygen at the corresponding rotameter or the O2-flush valve, or from a leak of fresh gas mixture either in a vaporizer or the selectatec manifold. The vaporizers carry a risk for vapor delivery at a concentration differing notably from the value set on the concentration dial. Therefore their accuracy must be checked periodically and the FGDUs checked for a leak after the addition to or the removal of a vaporizer from the selectatec manifold. The optimal technique for leak detection is the negative pressure test.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.