Zhonghua Wei Zhong Bing Ji Jiu Yi Xue · Mar 2013
[Use of an electromagnetic device for insertion of bedside nasojejunal feeding tube in critically ill patients].
- Yu-qi Liu, Li-sui He, Guo-liang Tan, Xu-ri Sun, and Zhi-liang Chen.
- Department of Critical Care Medicine, the Second Clinical Hospital of Fujian Medical University, Quanzhou, Fujian, China. annan1125@sina.com
- Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2013 Mar 1;25(3):171-3.
ObjectiveTo evaluate the efficacy of an electromagnetic device for correct bedside placement of nasojejunal feeding tube for patients in intensive care unit (ICU).MethodsThe clinical data of 109 patients in ICU who accepted bedside nasojejunal feeding tube placement from January 2010 to September 2012 were retrospectively analyzed. All the patients were divided into three groups according to the difference in type of nasojejunal feeding tube and the placement technique: control group 1 (n=48, Flocare feeding tube and bedside blind insertion group), control group 2 (n=28, Corflo(®) feeding tube and bedside blind insertion group), observation group (n=33, Corflo(®) feeding tube and electromagnetic tube placement device group). The success rate, the times of placement, duration of nasojejunal feeding, and safety were compared among three groups.ResultsThe success rate of control group 2 and observation group were higher than control group 1 (71.43%, 90.91% vs. 33.33%), rate of partial success and failure rate were lower than those of control group 1 (partial success rate: 17.86%, 3.03% vs. 35.42%; failure rate: 10.71%, 6.06% vs. 31.25%, all P<0.05), and no differences were found between control group 2 and observation group. The average times for successful placement in observation group was lower than that of control group 1 and control group 2 (1.6±0.5 vs. 6.6±3.2, 5.8±2.3, both P<0.05), and the average time for successful placement was shorter in observation group than that of control group 1 and control group 2 (12.48±3.78 minutes vs. 25.27±3.61 minutes, 23.58±4.87 minutes, both P<0.05), but there was no difference between control group 1 and control group 2. No complications occurred in all three groups.ConclusionPlacement of a nasojejunal tube with the aid of an electromagnetic device is an excellent method for enteral nutrition, as it is safer, more efficient, with high successful rate, less time spending, and easier to master for beginners.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.