- Takafumi Matsumoto, Yoko Sato, Satoshi Fukuda, Shinshu Katayama, Yuya Miyazaki, Makoto Ozaki, and Toru Kotani.
- Department of Anesthesiology and Intensive Care Medicine, Tokyo Women's Medical University, Japan.
- Intern. Med. 2015 Jan 1;54(7):731-5.
AbstractObjective Fibre-optic bronchoscopy with bronchoalveolar lavage (FOB-BAL) is an important tool for diagnosing and selecting treatment for acutely hypoxaemic patients with diffuse lung infiltrates. However, FOB-BAL carries a risk of significant hypoxaemia and subsequent tracheal intubation during and after the procedure. The application of FOB-BAL using a laryngeal mask airway (LMA) in combination with continuous positive airway pressure (CPAP) may minimize the incidence of hypoxaemia; however, the safety and efficacy of this procedure have not been investigated. Methods A retrospective chart review was performed from April to September 2013. Data regarding the recovered volume of BAL fluid, incidence of tracheal intubation within eight hours after the completion of FOB-BAL, respiratory and haemodynamic parameters and treatment modifications were collected for the evaluation. Results Ten trials of FOB-BAL using an LMA and CPAP were performed in nine patients with severe acute hypoxaemia associated with diffuse lung infiltrates. The BAL fluid recovery rate was 56%, and the procedure was completed without subsequent complications. In addition, the percutaneous arterial oxygen saturation decreased to 95.7%±3.8%, although it was never lower than 90.0% during the procedure, and no patients required intubation. Furthermore, the arterial blood pressure significantly but transiently decreased due to sedation, and the procedure yielded diagnostic information in all nine patients. Conclusion FOB-BAL using LMA and CPAP appears to be safe and effective in patients who develop severe acute hypoxaemia.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.