Clinical TrialMacrocirculation is not the sole determinant of respiratory induced variations in the reflection mode photoplethysmographic signal.
- L Nilsson, A Johansson, and S Kalman.
- Department of Anaesthesiology and Intensive Care, Linköping University Hospital, Linköping, Sweden. lena.nilsson@lio.se
- Physiol Meas. 2003 Nov 1;24(4):925-37.
AbstractPhotoplethysmography (PPG) is a non-invasive optical technique sensitive to variations in blood volume and perfusion in the tissue. Reflection mode PPG may have clinical advantages over transmission mode PPG. To improve clinical usefulness and further development of the reflection mode PPG, studies on factors that modify the signal are warranted. We studied the coherence between the respiratory induced intensity variations (RIIV) of the PPG signal and respiratory synchronous pressure variations in central venous pressure (CVP), peripheral venous pressure (PVP) and arterial blood pressure (ABP) during positive pressure ventilation on 12 patients under anaesthesia and on 12 patients with spontaneous breathing. During positive pressure ventilation the coherence between all signals was high. Inspiration was followed first by an increase in CVP, then by increases in ABP and PVP and lastly by RIIV indicating less back-scattered light. In spontaneously breathing patients the coherence was high, but the phases between the signals were changed. During inspiration, ABP decreased slightly before CVP, followed by a decrease in RIIV and PVP. The phase relation between RIIV and respiratory induced variation in macrocirculation changed with ventilatory mode, but not in a uniform way, indicating the influence of mechanisms other than macrocirculation involved in generating the RIIV signal.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.