• J Anaesthesiol Clin Pharmacol · Jul 2012

    Comparison of Cobra perilaryngeal airway (CobraPLA™) with flexible laryngeal mask airway in terms of device stability and ventilation characteristics in pediatric ophthalmic surgery.

    • Rani A Sunder, Renu Sinha, Anil Agarwal, Bala Chandran Sundara Perumal, and Sakthi Rajan Paneerselvam.
    • Department of Anaesthesiology and Intensive Care, Rajendra Prasad Institute of Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
    • J Anaesthesiol Clin Pharmacol. 2012 Jul 1;28(3):322-5.

    BackgroundSupraglottic airway devices play an important role in ophthalmic surgery. The flexible laryngeal mask airway (LMA™) is generally the preferred airway device. However, there are no studies comparing it with the Cobra perilaryngeal airway (CobraPLA™) in pediatric ophthalmic procedures.AimsTo analyze the intraoperative device stability and ability to maintain normocarbia of CobraPLA™ and compare it to that with flexible LMA™.Materials And MethodsNinety children of American Society for Anesthesiologists physical status 1 and 2, aged 3-15 years scheduled for elective ophthalmic surgeries were randomly assigned to either the CobraPLA™ or the flexible LMA™ group. After placement of each airway device, oropharyngeal leak pressure (OLP) was noted. Adequate seal of the devices was confirmed at an inspired pressure of 15 cm H(2)O and pressure-controlled ventilation was initiated. Device displacement was diagnosed if there was a change in capnograph waveform, audible or palpable gas leak, change in expired tidal volume to <8 ml/kg, end-tidal carbon-dioxide persistently >6 kPa, or need to increase inspired pressure to >18 cm H(2)O to maintain normocarbia.ResultsDemographic data, duration, and type of surgery in both the groups were similar. A higher incidence of intraoperative device displacement was noted with the CobraPLA™ in comparison to flexible LMA™ (P < 0.001). Incidence of displacement was higher in strabismus surgery (7/12). Insertion characteristics and ventilation parameters were comparable. The OLP was significantly higher in CobraPLA™ group (28 ± 6.8 cm H(2)O) compared to the flexible LMA™ group (19.9 ± 4.5 cm H(2)O) (P < 0.001). Higher surgeon dissatisfaction (65.9%) was seen in the CobraPLA™ group.ConclusionThe high incidence of device displacement and surgeon dissatisfaction make CobraPLA™ a less favorable option than flexible LMA™ in ophthalmic surgery.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.