J Anaesthesiol Clin Pharmacol · Jul 2012
Comparison of Cobra perilaryngeal airway (CobraPLA™) with flexible laryngeal mask airway in terms of device stability and ventilation characteristics in pediatric ophthalmic surgery.
- Rani A Sunder, Renu Sinha, Anil Agarwal, Bala Chandran Sundara Perumal, and Sakthi Rajan Paneerselvam.
- Department of Anaesthesiology and Intensive Care, Rajendra Prasad Institute of Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
- J Anaesthesiol Clin Pharmacol. 2012 Jul 1;28(3):322-5.
BackgroundSupraglottic airway devices play an important role in ophthalmic surgery. The flexible laryngeal mask airway (LMA™) is generally the preferred airway device. However, there are no studies comparing it with the Cobra perilaryngeal airway (CobraPLA™) in pediatric ophthalmic procedures.AimsTo analyze the intraoperative device stability and ability to maintain normocarbia of CobraPLA™ and compare it to that with flexible LMA™.Materials And MethodsNinety children of American Society for Anesthesiologists physical status 1 and 2, aged 3-15 years scheduled for elective ophthalmic surgeries were randomly assigned to either the CobraPLA™ or the flexible LMA™ group. After placement of each airway device, oropharyngeal leak pressure (OLP) was noted. Adequate seal of the devices was confirmed at an inspired pressure of 15 cm H(2)O and pressure-controlled ventilation was initiated. Device displacement was diagnosed if there was a change in capnograph waveform, audible or palpable gas leak, change in expired tidal volume to <8 ml/kg, end-tidal carbon-dioxide persistently >6 kPa, or need to increase inspired pressure to >18 cm H(2)O to maintain normocarbia.ResultsDemographic data, duration, and type of surgery in both the groups were similar. A higher incidence of intraoperative device displacement was noted with the CobraPLA™ in comparison to flexible LMA™ (P < 0.001). Incidence of displacement was higher in strabismus surgery (7/12). Insertion characteristics and ventilation parameters were comparable. The OLP was significantly higher in CobraPLA™ group (28 ± 6.8 cm H(2)O) compared to the flexible LMA™ group (19.9 ± 4.5 cm H(2)O) (P < 0.001). Higher surgeon dissatisfaction (65.9%) was seen in the CobraPLA™ group.ConclusionThe high incidence of device displacement and surgeon dissatisfaction make CobraPLA™ a less favorable option than flexible LMA™ in ophthalmic surgery.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.