    Minimal invasive lung support via umbilical vein with a double-lumen cannula in a neonatal lamb model: a proof of principle.

    • Florian Schmidt, J Kuebler, M Ganter, T Jack, L Meschenmoser, M Sasse, M Boehne, H Bertram, P Beerbaum, and H Koeditz.
    • Department of Pediatric Cardiology and Intensive Care Medicine, Medical School Hannover, Carl-Neuberg-Strasse 1, 30625, Hannover, Germany. schmidt.florian@mh-hannover.de.
    • Pediatr. Surg. Int. 2016 Jan 1; 32 (1): 75-82.

    PurposeAcute respiratory distress syndrome, with the need for invasive mechanical ventilation (MV) remains a major cause of neonatal mortality and morbidity. Although venovenous extracorporeal lung support (VV-ECLS) has become a standard of care procedure in neonatal patients with acute pulmonary failure there are no reports regarding the use of a double-lumen cannula for extracorporeal minimal invasive lung support via the umbilical vein.MethodsA neonatal lamb model was used (n = 3). Umbilical vein was cannulated with a double-lumen catheter allowing venovenous extracorporeal gas exchange. Cannula was positioned with its tip in the right atrium. VV-ECLS was started and ventilation was stopped. Providing oxygenation and CO2 removal solely through VV-ECLS hemodynamics, blood gases were measured.ResultsTotal VV-ECLS without MV was applied to all three neonatal lambs. Time on venovenous ECLS was 60, 120 and 120 min. Initial pCO2 was 60, 56 and 65 mmHg compared to 31, 32 and 32 mmHg at the end of VV-ECLS. Initial pO2 was 30, 27 and 26 mmHg compared to 22, 19 and 23 mmHg. Initial lactate was 5, 10 and 3.7 mmol/l compared to 13.3, 12.6 and 11.3 mmol/l at the end of VV-ECLS. MAP at baseline was 51, 52 and 65 mmHg compared to 36, 38 and 41 mmHg at the end of VV-ECLS. In all three lambs inotropes were admitted to maintain MAD >35 mmHg.ConclusionEven without mechanical ventilation we were able to sufficiently remove pCO2 with our new minimal invasive VV-ECLS using a double-lumen catheter via the umbilical vein, supporting the idea of a lung protective strategy in neonatal acute respiratory failure. pO2 was measured 22, 19 and 23 mmHg, respectively, at the end of VV-ECLS, at least partially caused by recirculation phenomenon, which could possibly be improved by different cannula design. Inotropic support was necessary during VV-ECLS to achieve targeted MAD > 35 mmHg. While technically feasible, this new approach might allow further research in the field of extracorporeal lung support and therefore will follow the concept of a lung protective strategy in acute neonatal respiratory failure.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…