Ann Fr Anesth Reanim · Jan 1994
[Pollution and retro-pollution by the distribution system of medical gases].
- J C Otteni, J Ancellin, J B Cazalaà, and F Clergue.
- Service d'Anesthésie-Réanimation Chirurgicale, CHU de Hautepierre, Strasbourg.
- Ann Fr Anesth Reanim. 1994 Jan 1;13(5):713-25.
AbstractThe anaesthetic machine, the recovery room or the ICU ventilator as well as any other simple oxygenation device can be accidentally supplied with a "wrong" gas, or a mixture of "wrong" and "true" gases, or a gas containing chemical impurities, as a result of one of the following causes: a) the source of the medical gas pipeline supply contains a "wrong" gas or impurities; b) the gas pipeline is polluted by a "wrong" gas or solvents, introduced during the installation or maintenance of the pipeline; c) the pipeline is polluted by a wrong gas at a point of inter-connection or cross-connection of two pipelines; d) supply of a "wrong" gas through wrong quick couplers connected to the pipeline; e) back flow of a gas in another pipeline supply through a defective gas mixer, which is today the most common cause of pipeline contamination or retropollution. It occurs with some types of mixers in case of absence or malfunction of non-return valves, associated with a pressure difference between the two gas lines. The means of prevention, recognition and emergency treatment of these events include: a) systematic removal of mixers and flowmeter-mixers from supplies when not in use; b) periodical checking of these devices for an accidental communication between the gases to be mixed; c) systematic use of an oxygen analyser for a continuous measurement of FIO2, especially when the machine is connected to the N2O pipeline supply; d) the presence of a reserve cylinder of oxygen connected to every anaesthetic machine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.