• Spinal cord · Dec 2004

    Treatment of spasticity with intrathecal Baclofen administration: long-term follow-up, review of 40 patients.

    • R Plassat, B Perrouin Verbe, P Menei, D Menegalli, J F Mathé, and I Richard.
    • Department of Physical Medicine and Rehabilitation, CHU Angers, France.
    • Spinal Cord. 2004 Dec 1;42(12):686-93.

    Study DesignCase series of a consecutive sample. Retrospective audit.ObjectiveTo analyze the long-term safety and efficacy of intrathecal baclofen (ITB), and technical incidents.SettingNeurosurgical and Physical Medicine Departments of two university hospitals in western France.MethodsThe medical records of 40 patients who underwent ITB pump placement for the treatment of severe chronic spasticity were reviewed. Patients were eligible independently of the origin of the spasticity (spinal cord origin 33, brain damage 8). They underwent a final assessment with clinical examination and questionnaire in 2001. Ashworth scale scores were assessed, patient satisfaction was rated on a visual analog scale (VAS), functional independence before and after treatment was classified as bed-ridden, wheelchair dependent or ambulant, and the frequency and nature of complications were noted.ResultsThe average follow-up period was of 4 years. The average Ashworth score at the final assessment was 1.8+/-0.6. Average patients satisfaction was 7.4/10+/-2.21 on VAS. In all, 85% would have undergone the procedure again if they had to make the decision. In 85% of the cases the ambulation status was unchanged. Technical incidents occurred at least once in 37% of the patients (due to the catheter in 58% and to the pump in 42%). They included catheter disconnections (4), migration (4), kinks (3), obstruction (3), development of fibrosis (3), disconnection of pump reservoir (2), porosity of pump membrane (2), unexplained pump dysfunction (4) leakage, and subcutaneous collection (5). Severe pharmacological side effects requiring transfer to intensive care unit occurred in 12% of cases, 80% of which were directly related to pump refill procedures.ConclusionITB remained effective in the long term and patients were satisfied. Nevertheless, complications were frequent, involving mainly the catheters, which would require further technical improvements.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…