• Clinical imaging · Mar 2014

    Comparative Study

    Clinical application of 3D VIBECAIPI-DIXON for non-enhanced imaging of the pancreas compared to a standard 2D fat-saturated FLASH.

    • Stefan Haneder, Katrin Koziel, John N Morelli, Philipp Riffel, Johannes Budjan, Stefan O Schoenberg, and Henrik J Michaely.
    • Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim - Heidelberg University, Germany.
    • Clin Imaging. 2014 Mar 1;38(2):142-7.

    PurposeTo compare a fast 3D VIBE sequence with Dixon fat saturation and CAIPIRINHA acceleration techniques (3D VIBE(CAIPI-DIXON)) to a standard 2D FLASH sequence with spectral fat saturation and conventional GRAPPA acceleration technique (2D Flash(GRAPPA-fs)) for non-enhanced imaging of the pancreas.Methods And MaterialsIn this retrospective, institutional review board-approved intra-individual comparison study, 29 patients (7 female, 22 male; mean age 60.4 ± 20.9 years) examined on a 48-channel 3.0-T MR system (MAGNETOM Skyra VD 13, Siemens Healthcare Sector, Germany) were included. 3D VIBE(CAIPI-DIXON) (TR/TE-3.95/2.5+1.27 ms; spatial resolution-1.2 × 1.2 × 3.0 mm(3); CAIPIRINHA 2 × 2 [1], acquisition time-0:12 min) and 2D Flash(GRAPPA-fs) (TR/TE-195/3.69 ms; 1.2 × 1.2 × 3.0 mm(3); GRAPPA 2, 3 × 0:21 min) sequences were performed in each subject in random order prior to the administration of an intravenous contrast agent. Two radiologists evaluated the images with regard to diagnostic preference. Semi-quantitative signal ratios were calculated for the pancreas versus the liver, spleen, muscle, and visceral fat. Inter-reader agreement was calculated using unweighted Cohen's kappa. Signal ratio results were analyzed using a univariate analysis of variance. Additional signal-to-noise (SNR) measurements were performed in a phantom.Results3D VIBE(CAIPI-DIXON) was preferred in 72.4% (both readers) and 2D Flash(GRAPPA-fs) in 3.4%/6.9% (reader 1/2) of cases with a kappa value of 0.756. The main reasons for this preference were homogenous fat saturation with 3D VIBE(CAIPI-DIXON) and reduced motion artifacts due to a faster acquisition, leading to improved delineation of the pancreas. Signal ratios of pancreatic to fat signal for 3D VIBE(CAIPI-DIXON) (10.08 ± 3.48) and 2D Flash(GRAPPA-fs) (6.53 ± 3.07) were statistically different (P<.001). However, no additional statistically significant differences in signal ratios were identified (range: 0.73 ± 0.18 to 1.37 ± 0.40; .514Conclusion3D VIBE(CAIPI-DIXON) enables robust pancreatic imaging with a shorter time and improved fat suppression relative to conventional 2D Flash(GRAPPA-fs). At an acquisition time of 12 seconds, 3D VIBE(CAIPI-DIXON) can be obtained in considerably less time than standard fat-saturated VIBE sequences.Copyright © 2014 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.