Anesthesia and analgesia · Dec 2014
Absolute and trend accuracy of a new regional oximeter in healthy volunteers during controlled hypoxia.
- Daniel Redford, Samata Paidy, and Faisal Kashif.
- From the *Department of Anesthesiology, University of Arizona Medical Center, Tucson, Arizona; and †Masimo Corporation, Irvine, California.
- Anesth. Analg.. 2014 Dec 1;119(6):1315-9.
BackgroundTraditional patient monitoring may not detect cerebral tissue hypoxia, and typical interventions may not improve tissue oxygenation. Therefore, monitoring cerebral tissue oxygen status with regional oximetry is being increasingly used by anesthesiologists and perfusionists during surgery. In this study, we evaluated absolute and trend accuracy of a new regional oximetry technology in healthy volunteers.MethodsA near-infrared spectroscopy sensor connected to a regional oximetry system (O3™, Masimo, Irvine, CA) was placed on the subject's forehead, to provide continuous measurement of regional oxygen saturation (rSO2). Reference blood samples were taken from the radial artery and internal jugular bulb vein, at baseline and after a series of increasingly hypoxic states induced by altering the inspired oxygen concentration while maintaining normocapnic arterial carbon dioxide pressure (PaCO2). Absolute and trend accuracy of the regional oximetry system was determined by comparing rSO2 against reference cerebral oxygen saturation (SavO2), that is calculated by combining arterial and venous saturations of oxygen in the blood samples.ResultsTwenty-seven subjects were enrolled. Bias (test method mean error), standard deviation of error, standard error of the mean, and root mean square accuracy (ARMS) of rSO2 compared to SavO2 were 0.4%, 4.0%, 0.3%, and 4.0%, respectively. The limits of agreement were 8.4% (95% confidence interval, 7.6%-9.3%) to -7.6% (95% confidence interval, -8.4% to -6.7%). Trend accuracy analysis yielded a relative mean error of 0%, with a standard deviation of 2.1%, a standard error of 0.1%, and an ARMS of 2.1%. Multiple regression analysis showed that age and skin color did not affect the bias (all P > 0.1).ConclusionsMasimo O3 regional oximetry provided absolute root-mean-squared error of 4% and relative root-mean-squared error of 2.1% in healthy volunteers undergoing controlled hypoxia.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.