Clinical Trial
A reliable, non-invasive measurement tool for anisotropy in normal skin and scar tissue.
- Pauline D H M Verhaegen, Evelien M Res, Arna van Engelen, Esther Middelkoop, and Paul P M van Zuijlen.
- Association of Dutch Burn Centres, Beverwijk, The Netherlands.
- Skin Res Technol. 2010 Aug 1; 16 (3): 325-31.
BackgroundAnisotropy of the skin varies depending on different locations and pathological conditions. Currently, no reliable non-invasive measurement tool is available for tissue anisotropy. The Reviscometer is an anisotropy measurement tool that measures the resonance running time (RRT) of a shock wave. This study was initiated to establish the reliability of the Reviscometer on normal skin and scars, and to provide basic information on tissue alignment in normal skin and scars.MethodsFifty volunteers and 50 patients underwent measurements on normal skin and scars, respectively. All measurements were performed by the same two observers. Measurements on normal skin were performed on the forearm, upper arm, and abdomen.ResultsThe results showed that the intraclass correlation coefficient of the inter-observer reliability was > or =0.79 on normal skin and > or =0.86 on scars. In normal skin, the highest mean RRT was found on the abdomen (156.4+/-48.8), followed by the upper arm (123.2+/-33.6) and the forearm (112.5+/-24.3). A significantly lower mean RRT was found in scars (52.3+/-21.9) compared with normal skin (91.6+/-37.7).ConclusionReviscometer measurements were reliable for normal skin and scars. In addition, clear differences between scars and normal skin but also within different locations on normal skin were identified. The Reviscometer can be considered for the evaluation of the efficacy of different treatments.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.