• AJR Am J Roentgenol · Sep 1998

    Comparative Study

    Usefulness of optimized gadolinium-enhanced fast fluid-attenuated inversion recovery MR imaging in revealing lesions of the brain.

    • E R Melhem, R J Bert, and R E Walker.
    • Department of Radiology, Boston University Medical Center, MA 02118, USA.
    • AJR Am J Roentgenol. 1998 Sep 1; 171 (3): 803-7.

    ObjectiveThe purpose of this study was to compare the contrast enhancement of lesions of the brain revealed by gadolinium-enhanced optimized fast fluid-attenuated inversion recovery (FLAIR) MR imaging with that of lesions on gadolinium-enhanced optimized T1-weighted spin-echo MR imaging.Subjects And MethodsUsing computer simulations, we optimized the fast FLAIR parameters (TR, TEeff, and inversion time) and the T1-weighted spin-echo parameters (TR and TE) to provide maximum difference in signal intensity between enhancing lesions of the brain and white matter. Seventy-six consecutive patients referred for single-dose gadolinium-enhanced MR imaging of the brain underwent both optimized techniques, which were matched for spatial resolution, bandwidth, and number of excitations. The gadolinium-enhanced fast FLAIR and T -weighted spin-echo MR images were evaluated independently by two observers for number and size of enhancing lesions and for the degree of gray-white matter differentiation. Contrast-to-noise ratios were measured for enhancing lesions 1.0 cm or larger in diameter using 8 x 8 pixel regions of interest in the enhancing lesions and normal white matter.ResultsThe most revealing parameters for fast FLAIR MR imaging proved to be a TR of 1500 msec, an inversion time of 683 msec, and a TEeff of 16 msec. For T1-weighted spin-echo MR imaging, the optimized parameters were a TR of 550 msec and a TE of 16 msec. In 28 patients, we saw enhancing lesions of the brain with at least one MR imaging technique. More lesions were seen on the T1-weighted spin-echo sequence (n = 141) than on the fast FLAIR sequence (n = 94) (p < .03). Gray-white matter differentiation was significantly better on the fast FLAIR sequence (p < .001). Contrast-to-noise ratios of enhancing lesions were greater on the T1-weighted spin-echo sequence (p < .001).ConclusionIn this study, optimized gadolinium-enhanced conventional T1-weighted spin-echo MR imaging proved superior to gadolinium-enhanced fast FLAIR MR imaging in revealing lesions of the brain.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…