-
Comparative Study Observational Study
A comparison of the I-Gel supraglottic device with endotracheal intubation for bronchoscopic lung volume reduction coil treatment.
- Julian Arevalo-Ludeña, Jose Juan Arcas-Bellas, Rafael Alvarez-Rementería, Javier Flandes, Laura Morís, and Luis E Muñoz Alameda.
- Department of Anesthesiology, University Hospital Fundacion Jimenez Diaz, Madrid, Spain. Electronic address: jarevalo@fjd.es.
- J Clin Anesth. 2016 Jun 1; 31: 137-41.
Study ObjectiveTo compare the use of the I-gel airway with orotracheal intubation (OTI) for bronchoscopic lung volume reduction (BLVR) coil treatment in patients with severe chronic obstructive pulmonary disease (COPD) with heterogeneous emphysema, since it has been proved that supraglottic airways have lower incidence of postoperative respiratory complaints compared to OTI.DesignA comparative, prospective observational study was designed to assess the use of the I-gel airway compared with the OTI.SettingBronchoscopy room at the University Hospital Fundación Jimenez Diaz, Madrid. Tertiary care center.PatientsThirty-three procedures were carried out in 22 patients diagnosed with COPD with severe heterogeneous emphysema undergoing BLVR coil treatment under general anaesthesia.InterventionSeventeen procedures were carried out with I-gel and 16 with endotracheal tube. Airway device choice was left to the attendant anesthesiologist.MeasurementsTidal volume, peak pressure, and the presence of gas leaks were compared. Adverse events during the procedure and within the first 3 hours later were also recorded.Main ResultsVentilation parameters obtained showed no significant differences. Mean tidal volume was 466.6 ± 28.2 mL and 478.7 ± 34.0 mL (P > .05), mean peak pressure was 17.9 ± 2.5 cmH2O and 19.4 ± 2.4 cmH2O (P > .05) and mean gas leaks was 71 ± 17.6 mL and 79 ± 15.5 mL (P > .05) for I-gel group (IgelG) and endotracheal tube group respectively. No serious complications were reported. One case of pneumothorax was reported in the endotracheal tube group, which was resolved with a chest drainage tube without further complications.ConclusionThe I-gel airway ensures appropriate ventilation and makes the use of the flexible fiberoptic bronchoscope quite easy. Therefore, we consider that the I-gel device is an effective and safe alternative to classical OTI for airway management in COPD patients with severe heterogeneous emphysema undergoing BLVR coil treatment.Copyright © 2016 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.