-
- Jorrit-Jan Verlaan, Everine B van de Kraats, F Cumhur Oner, Theo van Walsum, Wiro J Niessen, and Wouter J A Dhert.
- Department of Orthopaedics, University Medical Center Utrecht, Utrecht, The Netherlands. jj.verlaan@wxs.nl
- Spine. 2005 Aug 15; 30 (16): 1840-5.
Study DesignIn a human cadaveric burst fracture model, the amount of endplate fracture reduction after posterior instrumentation and balloon vertebroplasty was investigated quantitatively.ObjectivesTo assess, in a burst fracture model, the vertebral body and adjacent disc heights, in parallel sagittal planes with 3-dimensional (3D) rotational x-ray imaging, at various phases during pedicle screw fixation and subsequent balloon vertebroplasty.Summary Of Background DataIn recent human cadaveric thoracolumbar fracture studies, it was found that vertebral body height could be restored significantly with inflatable bone tamps. However, limited quantitative data exist on the amount of fracture reduction that can be achieved and how much of the reduction will be lost after deflation and removal of the bone tamps before the cement is injected.MethodsTwenty burst fractures were created and balloon vertebroplasty with calcium phosphate cement was performed after pedicle screw instrumentation. A 3D dataset was obtained during the following phases: intact, fractured, after reduction and stabilization with pedicle screws, after inflation of the balloons, after deflation and removal of the balloons, after injection of the cement. The fractured vertebral body and adjacent disc heights were measured from five reconstructed sagittal images and compared for the six phases of the procedure. Furthermore, the difference between the vertebral body height centrally and peripherally was calculated.ResultsThe mean vertebral body height at the thoracic level was Tintact = 19.5 +/- 2.2 mm, Tfractured = 14.6 +/- 3.8 mm, Treduction = 17.3 +/- 2.2 mm, Tinflation = 20.1 +/- 2.0 mm, Tdeflation = 18.0 +/- 2.0 mm, and Tcement = 17.8 +/- 1.8 mm. The overall change in vertebral body height between these phases was significant (P < 0.001). At the lumbar level the mean vertebral body height was Tintact = 23.2 +/- 3.8 mm, Tfractured = 14.7 +/- 3.0 mm, Treduction = 18.4 +/- 2.5 mm, Tinflation = 23.2 +/- 3.5 mm, Tdeflation = 19.3 +/- 2.3 mm, and Tcement = 20.2 +/- 2.8 mm. The overall change in MCVBH between these phases was also significant (P < 0.001). The increase in vertebral body height resulted in a decrease of the adjacent disc height. No difference was found for the amount of endplate reduction in the center or at the periphery. No leakage of cement was detected in the spinal canal.ConclusionsReduction of endplate fractures, both in the center and at the periphery, seems feasible and safe with combined fracture reduction and balloon vertebroplasty. The endplate fracture reduction that was gained by inflation of the bone tamps could not be maintained after deflation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.