Observational Study
Continuous monitoring of haemoglobin concentration after in-vivo adjustment in patients undergoing surgery with blood loss.
- D Frasca, H Mounios, B Giraud, M Boisson, B Debaene, and O Mimoz.
- Department of Anaesthesia and Intensive Care, University Hospital of Poitiers, Poitiers, France.
- Anaesthesia. 2015 Jul 1;70(7):803-9.
AbstractNon-invasive monitoring of haemoglobin concentration provides real-time measurement of haemoglobin concentration (SpHb) using multi-wavelength pulse co-oximetry. We hypothesised that in-vivo adjustment using the mean of three haemoglobinometer (HemoCue®) measurements from an arterial blood sample at the first SpHb measurement (HCueART) would increase the accuracy of the monitor. The study included 41 adults for a total of 173 measurements of haemoglobin concentration. In-vivo adjusted SpHb was automatically calculated by the following formula: in-vivo adjusted SpHb = unadjusted SpHb - (SpHb - HCueART). The accuracy of in-vivo adjusted SpHb was compared with SpHb retrospectively adjusted using the same formula, except for haemoglobin level which was assessed at the central laboratory and then compared with all other available invasive methods of haemoglobin measurement (co-oximetry, HbSAT; arterial HemoCue, HCueART; capillary HemoCue, HCueCAP). Compared with laboratory measurement of haemoglobin concentration, bias (precision) for unadjusted SpHb, in-vivo adjusted SpHb, retrospectively adjusted SpHb, HbSAT, HCueART and HCueCAP were -0.4 (1.4), -0.3 (1.1), -0.3 (1.1), -0.6 (0.7), 0.0 (0.4) and -0.5 (1.2) g.dl(-1) , respectively. In-vivo adjustment of SpHb values using the mean of three arterial HemoCue measurements improved the accuracy of the device similar to those observed after a retrospective adjustment using central laboratory haemoglobin level.© 2015 The Association of Anaesthetists of Great Britain and Ireland.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.