Anaesthesia
-
Pain diagnosis and management would benefit from the development of objective markers of nociception and pain. Current research addressing this issue has focused on five main strategies, each with its own advantages and disadvantages. ⋯ Although each strategy has shown areas of promise, there are currently no validated objective markers of nociception or pain that can be recommended for clinical use. This article introduces the most important developments in the field and highlights shortcomings, with the aim of allowing the reader to make informed decisions about what trends to watch in the future.
-
We compared the McGrath® Series 5 videolaryngoscope with the Macintosh laryngoscope for double-lumen tracheal tube placement in patients with a predicted good glottic view on assessment of the airway. An initial laryngoscopy was performed using the Macintosh laryngoscope; 96 patients with Cormack and Lehane grade-1 or -2a views were randomly assigned to undergo intubation using either the McGrath or Macintosh device. ⋯ However, in 18 non-randomised patients with Cormack and Lehane grade ≥ 2b on initial laryngoscopy using the Macintosh, the glottic view was improved on intubation with the McGrath videolaryngoscope, with a total success rate of double-lumen tube placement of 94.4% and mean (SD) intubation time of 50.0 (18.6) s. We recommend that in patients with a low airway risk index score requiring intubation with a double-lumen tracheal tube, the Macintosh laryngoscope is used as the first device and the McGrath videolaryngoscope is used only if this provides a poor glottic view.
-
Comparative Study
Comparison of the identification and ease of use of two alarm sound sets by critical and acute care nurses with little or no music training: a laboratory study.
The melodic alarm sound set for medical electrical equipment that was recommended in the International Electrotechnical Commission's IEC 60601-1-8 standard has proven difficult for clinicians to learn and remember, especially clinicians with little prior formal music training. An alarm sound set proposed by Patterson and Edworthy in 1986 might improve performance for such participants. In this study, 31 critical and acute care nurses with less than one year of formal music training identified alarm sounds while they calculated drug dosages. ⋯ The mean (SD) percentage of alarms correctly identified by nurses was 51.3 (25.6)% for the IEC alarm set and 72.1 (18.8)% for the Patterson-Edworthy alarms (p = 0.016). Nurses using the Patterson-Edworthy alarm sound set reported that it was easier to distinguish between alarm sounds than did nurses using the IEC alarm sound set (p = 0.015). Principles used to construct the Patterson-Edworthy alarm sounds should be adopted for future alarm sound sets.