-
Randomized Controlled Trial
Haemoconcentration of residual cardiopulmonary bypass blood using Hemosep(®) : a randomised controlled trial.
- M Hogan, A Needham, E Ortmann, F Bottrill, T J Collier, M W Besser, and A A Klein.
- Department of Anaesthesia and Intensive Care, Papworth Hospital, Cambridge, UK.
- Anaesthesia. 2015 May 1;70(5):563-70.
AbstractCardiac surgery and cardiopulmonary bypass are associated with haemodilution, activation of haemostasis and blood transfusion. We undertook a randomised controlled trial that included 53 patients in order to compare autotransfusion of residual cardiopulmonary bypass blood with residual blood concentrated using the novel Hemosep(®) device. There was no difference in patients' mean (SD) haemoglobin concentration after autotransfusion of unprocessed blood compared with Hemosep; 103.5 (10.2) g.l(-1) vs 106.2 (12.4) g.l(-1), respectively, p = 0.40. The mean (SD) change in haemoglobin concentration after autotransfusion was 5.9 (5.3) g.l(-1) in the control group compared with 4.9 (6.3) g.l(-1) in the Hemosep group, p = 0.545. Adjusted for baseline haemoglobin concentrations, the estimated mean (95% CI) difference in change in haemoglobin concentration (control vs Hemosep) was 0.57 (-2.65 to 3.79) g.l(-1), p = 0.72. This was despite Hemosep's reducing the weight of the blood from a mean (SD) of 778.7 (243.0) g to 607.3 (248.2) g, p < 0.001. The haemoglobin concentration in the processed blood increased from a mean (SD) of 87.0 (15.1) g.l(-1) to 103.7 (17.4) g.l(-1), p < 0.001. We conclude that Hemosep is capable of haemoconcentration when employed to process residual cardiopulmonary bypass blood, but that this is insufficient to increase patient haemoglobin.© 2015 The Association of Anaesthetists of Great Britain and Ireland.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.