• Anesthesiol Res Pract · Jan 2015

    Comparison of the Disposable Streamlined Liner of the Pharynx Airway and the Disposable I-gel in Anaesthetized, Paralyzed Adults: A Randomized Prospective Study.

    • Khaled El-Radaideh, Ala A Alhowary, and Diab Bani Hani.
    • Department of Anesthesiology, Faculty of Medicine, Jordan University of Science and Technology, P.O. Box 953, Irbid 21110, Jordan.
    • Anesthesiol Res Pract. 2015 Jan 1; 2015: 971059.

    AbstractIntroduction. This study compared streamlined liner of the pharynx airway (SLIPA) and I-gel noninflatable, single-use, supraglottic airway device (SAD) performance in anesthetized, paralyzed adults. Methods. Eighty adults (ASA physical statuses I-III) who were undergoing elective procedures under general anesthesia with an SAD were enrolled in this prospective, randomized, single-blind study. Subjects were randomly and evenly assigned to the SLIPA or I-gel group for intraoperative airway management. Ease and number of insertions, insertion time, oropharyngeal sealing pressure, hemodynamic response, oxygen saturation (SpO2), end-tidal CO2 (EtCO2), and peri- and postoperative complications were examined. Results. The SLIPA and I-gel devices were successfully inserted in 100% and 95% of subjects, respectively. In two I-gel subjects (5%), ventilation was not possible after two attempts, but a size 55 SLIPA was successfully inserted in both cases. Forty-two and 38 patients were ultimately included in the SLIPA and I-gel groups, respectively. Insertion time was significantly shorter with the SLIPA (11.19 ± 3.03 s) than with the I-gel (15.05 ± 6.37 s, P = 0.003). Oropharyngeal sealing pressure was significantly higher in SLIPA (28.76 ± 3.11 cmH2O) than in I-gel (25.9 ± 3.65 cmH2O) subjects (P = 0.001). Blood staining occurred more frequently in SLIPA (n = 8, 19.0%) than in I-gel (n = 5, 13.2%) patients (P < 0.01). Heart rate, mean arterial blood pressure, SpO2, and EtCO2 were not significantly different between groups. Conclusion. Although blood staining incidence was higher, SLIPA insertion was easier and faster than I-gel insertion. The SLIPA provided better airway sealing pressure. Both devices had similar mechanical ventilation and oxygenation characteristics and comparable hemodynamic stability. Both noninflatable SADs are useful, but SLIPA rapid insertion and good airway sealing make it an effective alternative to the I-gel.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…