• Acta radiologica · Oct 2012

    Multicenter Study Comparative Study Clinical Trial

    An observational study to evaluate the efficiency and safety of ioversol pre-filled syringes compared with ioversol bottles in contrast-enhanced examinations.

    • Thomas J Vogl, Johannes Wessling, and Boris Buerke.
    • Department of Diagnostic and Interventional Radiology, Johann Wolfgang Goethe University Frankfurt, Germany. t.vogl@em.uni-frankfurt.de
    • Acta Radiol. 2012 Oct 1; 53 (8): 914-20.

    BackgroundThe use of pre-filled syringes for contrast media (CM) administration allows efficient and optimized workflow during radiologic diagnostic procedures, and reduces the risk of contamination, providing benefits for both patients and healthcare workers.PurposeTo compare the efficiency and safety of ioversol (Optiray(TM)) bottles and pre-filled syringes in clinical practice.Material And MethodsThis was an observational, non-interventional, prospective, multicenter study conducted at 72 centers in Germany. Patients undergoing contrast-enhanced computed tomography (CT) examinations with ioversol were enrolled. The use of ioversol bottles and pre-filled syringes in the diagnostic procedure was recorded in terms of efficiency (residual volume, re-use of CM) and safety (adverse events [AEs]).ResultsA total of 10,836 patients were enrolled and included in this study. Ioversol bottles and syringes were used in 72% and 28% of cases, respectively. Analysis of the volume of CM in bottles before and after examinations, together with the volume used during the examination, suggested that in 22.5% of cases a new bottle was connected during the procedure. Further analysis revealed that in 80.2% of cases, the remaining volume of CM in the bottles could potentially be used for subsequent investigations, compared with <1% of cases for pre-filled syringes. For the total study population, AEs and serious AEs were reported in 30 (0.28%) and four (0.037%) patients, respectively, with no significant difference observed between ioversol bottles and syringes.ConclusionAdministration of ioversol for contrast-enhanced CT examinations is associated with a low incidence of AEs and is generally safe and well tolerated. Ioversol pre-filled syringes were associated with lower residual volumes and less potential re-use compared with bottles.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.