-
Mayo Clinic proceedings · Oct 2013
Comparative StudyImproving affordability through innovation in the surgical treatment of mitral valve disease.
- Rakesh M Suri, Jeffrey E Thompson, Harold M Burkhart, Marianne Huebner, Bijan J Borah, Zhuo Li, Hector I Michelena, Sue L Visscher, Veronique L Roger, Richard C Daly, David J Cook, Maurice Enriquez-Sarano, and Hartzell V Schaff.
- Division of Cardiovascular Surgery, Mayo Clinic, Rochester, MN. Electronic address: suri.rakesh@mayo.edu.
- Mayo Clin. Proc. 2013 Oct 1; 88 (10): 1075-84.
ObjectiveTo determine whether technically innovative cardiac surgical platforms (ie, robotics) deployed in conjunction with surgical process improvement (systems innovation) influence total hospital costs to address the concern that expanding adoption might increase health care expenses.Patients And MethodsWe studied 185 propensity-matched patient pairs (370 patients) undergoing isolated conventional open vs robotic mitral valve repair with identical repair techniques and care teams between July 1, 2007, and January 31, 2011. Two time periods were considered, before the implementation of system innovations (pre-July 2009) and after implementation. Generalized linear mixed models were used to estimate the effect of the type of surgery on cost while adjusting for a time effect.ResultsBaseline characteristics of the study patients were similar, and all patients underwent successful mitral valve repair with no early deaths. Median length of stay (LOS) for patients undergoing open repair was unchanged at 5.3 days (P=.636) before and after systems innovation implementation, and was lower for robotic patients at 3.5 and 3.4 days, respectively (P=.003), throughout the study. The overall median costs associated with open and robotic repair were $31,838 and $32,144, respectively (P=.32). During the preimplementation period, the total cost was higher for robotic ($34,920) than for open ($32,650) repair (P<.001), but during the postimplementation period, the median cost of robotic repair ($30,606) became similar to that of open repair ($31,310) (P=.876). The largest decrease in robotic cost was associated with more rapid ventilator weaning and shortened median intensive care unit LOS, from 22.7 hours before July 2009 to 9.3 hours after implementation of systems innovations (P<.001).ConclusionFollowing the introduction of systems innovation, the total hospital cost associated with robotic mitral valve repair has become similar to that for a conventional open approach, while facilitating quicker patient recovery and diminished utilization of in-hospital resources. These data suggest that innovations in techniques (robotics) along with care systems (process improvement) can be cost-neutral, thereby improving the affordability of new technologies capable of improving early patient outcomes.Copyright © 2013 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.