- Paul A Bottomley, Ananda Kumar, William A Edelstein, Justin M Allen, and Parag V Karmarkar.
- SurgiVision, Inc., Suite B307, 1101 East 33rd Street, Baltimore, Maryland 21218, USA. bottoml@mri.jhu.edu
- Med Phys. 2010 Jul 1; 37 (7): 3828-43.
PurposeThe presence of implanted electronic devices with conducting leads and electrodes are contraindicated for magnetic resonance imaging (MRI), denying many patients its potential benefits. The prime concern is MRI's radio frequency (RF) fields, which can cause elevated local specific absorption rates (SARs) and potential heat injury. The purpose of this article is to develop and compare a range of passive implantable "MRI-safe" lead designs.MethodsConducting leads incorporating different lengths (3-75 cm), insulation thicknesses (0-105 microm), resistances (100-3000 omega), coiled conductors (inner diameter < or = 1.2 mm), high-impedance (135-2700 omega) RF traps, and single-coiled and triple-coiled coaxial-wound "billabong" leads with reversed coil sections that oppose and reduce the induced current, are investigated both experimentally using local temperature measurements, and by numerical full-wave electromagnetic field analysis of the local SAR, in three different-sized bioanalogous model saline-gel phantoms at 1.5 T MRI and 4 W/kg exposure.ResultsIn all designs, the maximum computed 1 g average SAR and experimental temperature rise occur at the bare electrodes. Electrode heating increases with lead insulation thickness and peaks for uncoiled leads 25-50 cm long. A reasonable match between computed SAR and the point SAR estimated from thermal sensors obtained by approximating the computation volume to that of the thermal probes. Factors that maximize the impedance of leads with resistive, coiled, RF trap and billabong elements can effectively limit heating below 1-2 degrees, but folded lead configurations can be a concern. The RF trap and billabong designs can both support multiple conductors and electrodes, with billabong prototype leads also heating <1 degrees C when tested for 3 T MRI.ConclusionsLead insulation and length strongly affect implanted lead safety to RF exposure during MRI. Lead designs employing impedance and reversed winding sections offer hope for the development of passive, MRI-safe, implantable conducting leads for future human use.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.