    Abnormal electrical stimulus of an intra-aortic balloon pump with concurrent support with continuous veno-venous hemodialysis.

    • P G Sakiewicz, E Wright, O Robinson, R Mercer, K Kickel, and E P Paganini.
    • Department of Nephrology and Hypertension, Cleveland Clinic Foundation, Ohio 44195, USA.
    • ASAIO J. 2000 Jan 1; 46 (1): 142-5.

    AbstractMalfunction of electronic medical support apparatus utilized in the ICU usually causes system failure. We report several occurrences of a potentially dangerous interaction between a continuous veno-venous hemodialysis (CVVHD) system and an intra-aortic balloon pump (IABP) counterpulsation device in four patients requiring both systems. The patients had acute renal failure in the face of multi-organ failure and were dependent upon the balloon pump for pressure support. Electrical interference created by the roller pump action of the CVVHD system was identified by the balloon pump as cardiac in origin, and it responded by inflation and deflation. As the blood pump rate was reduced, the interference reduced to the point of complete cessation when the blood pump was shut down. Whereas one patient transiently had a significant drop of mean arterial pressure (from 70 +/- 4 to 40 +/- 2 mm Hg) the other observed occurrences had no clinically significant sequelae. Electrocardiogram (ECG) tracings identified the abnormal stimulus and systematic review identified as potential sources for the creation of this interference static electricity buildup, piezoelectric properties of the polyvinyl chloride tubing, and, possibly but less likely, radiofrequency interference. A newer generation ECG cable and advanced cardiac rhythm recognition software (CardioSync) have been introduced with the Datascope System 98, and the ECG interference, although still occasionally present, does not cause erratic inflation and deflation of the intra-aortic balloon pump. Interference between different electrical support systems may occur, and we suggest that the systems be tested for compatibility before combined use and that older equipment be more rigorously tested for potential clinically significant interference.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.