• Paediatric anaesthesia · Aug 2015

    Continuous minimally invasive cardiac output monitoring with the COstatus in a neonatal swine model: recalibration is necessary during vasoconstriction and vasodilation.

    • Alvaro F Cisternas, Manuel Martin-Flores, and Robin D Gleed.
    • Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY, USA.
    • Paediatr Anaesth. 2015 Aug 1;25(8):852-9.

    BackgroundThe COstatus monitor measures cardiac output via the transpulmonary ultrasound dilution method (COTPUD ) after injection of normal saline, and can calculate continuous cardiac output (CCO) from the arterial pressure waveform. The relationship between arterial waveform and COTPUD however, might be degraded during vasoconstriction/vasodilation.ObjectivesTo examine if recalibration of arterial waveform-derived CCO is required during mild vasoconstriction/vasodilation.MethodsIn 10 anesthetized piglets (6.6-10.1 kg), two COstatus monitors calculated the CCO from the same femoral arterial waveform before and during infusions of phenylephrine (PE; 1 or 3 mg·kg(-1) ·min(-1) ) and sodium nitroprusside (SNP; 1 or 5 mg·kg(-1) ·min(-1) ), administered in random order. One monitor was recalibrated (CCORecal ) after each intervention, while the other monitor was not (CCONon-Recal ). Recalibration was performed with COTPUD with 1 ml·kg(-1) normal saline as indicator. The effects of each infusion on hemodynamic parameters were compared with baseline using paired t-tests. The bias, limits of agreement (LOA), and percentage error between simultaneous measurements (CCORecal and CCONon-Recal ) were examined with Bland-Altman plots.ResultsInfusion of PE significantly increased COTPUD , heart rate (HR), and arterial pressures but not systemic vascular resistance (SVR). Infusion of SNP decreased arterial pressures without affecting COTPUD , HR, and SVR. There was no bias between CCORecal and CCONon-Recal at the baseline, but a small bias was observed during PE and SNP infusions. The LOA increased approximately 10 fold during vasoconstriction and vasodilation. The percentage error increased from ≤ 5% to 32% and 27% during PE and SNP infusions, respectively.ConclusionContinuous cardiac output (CO) measured with the COstatus monitor requires recalibration during vasoconstriction and vasodilation, even if changes in COTPUD or SVR are not substantial.© 2015 John Wiley & Sons Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…