-
- Maura A Watson, Christopher S King, Aaron B Holley, David L Greenburg, and Jeffrey A Mikita.
- Pulmonary and Critical Care Medicine, Walter Reed Army Medical Center, 3831 Rodman Street NW, F30, Washington DC 20016, USA.
- Resp Care. 2009 Apr 1; 54 (4): 467-73.
BackgroundVocal cord dysfunction (VCD) is difficult to diagnose. Laryngoscopy while the patient is symptomatic is the accepted standard method to establish a diagnosis of VCD, but patient characteristics and spirometry values are thought to be useful for predicting VCD. We sought to identify clinical and spirometric variables that suggest VCD.MethodsWe performed 2 parallel studies. First, 3 staff pulmonologists (who were blinded to the laryngoscopy results), scored 3 flow-volume loops from each PFT session on the likelihood that the inspiratory curve indicated VCD. We also performed a cross-sectional study of clinical characteristics and spirometric data from all patients who underwent laryngoscopy for any indication, including suspected VCD, over a 3-year period. We compared the laryngoscopy findings to the clinical characteristics, spirometry results, and the pulmonologists' assessments of the flow-volume loops. We used multivariate logistic regression to identify independent predictors of VCD.ResultsThe pulmonologists agreed about which flow-volume loops predicted VCD (quadratic kappa range 0.55-0.76), but those ratings were not predictive of laryngoscopic diagnosis of VCD. During the study period, 226 patients underwent laryngoscopy. One hundred (44%) were diagnosed with VCD. Independent predictors of VCD included female sex (odds ratio 2.72, 95% confidence interval 1.55-4.75) and obesity (body mass index > 30 kg/m(2)) (odds ratio 2.06, 95% confidence interval 1.12-3.80). With spirometric data from the effort that had the best forced-vital-capacity, multivariate analysis found the ratio of the forced inspiratory flow at 25% of the inspired volume to forced inspiratory flow at 75% of the inspired volume (FIF(25%/75%)) predictive of VCD (odds ratio 1.97, 95% confidence interval 1.12-3.44). The diagnostic performance of these characteristics was poor; the area under the receiver-operating-characteristic curve was 0.68. With the spirometric data from the effort that had the subjectively determined best inspiratory curve, and after controlling for the reproducibility of the inspiratory curves, multivariate analysis found none of the spirometric variables predictive of VCD.ConclusionsVCD remains difficult to predict with spirometry or flow-volume loops. If VCD is suspected, normal flow-volume loop patterns should not influence the decision to perform laryngoscopy.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.