• Pediatric research · Jul 2005

    Aerosol deposition in neonatal ventilation.

    • Jean C Dubus, Laurent Vecellio, Michele De Monte, James B Fink, Daniel Grimbert, Jerome Montharu, Chantal Valat, Neil Behan, and Patrice Diot.
    • INSERM U618, Service de Pneumologie, CHU Bretonneau, 2 Boulevard Tonnellé, 37044 Tours, France.
    • Pediatr. Res. 2005 Jul 1; 58 (1): 10-4.

    AbstractLung deposition of inhaled drugs in ventilated neonates has been studied in models of questionable relevance. With conventional nebulizers, pulmonary deposition has been limited to 1% of the total dose. The objective of this study was to assess lung delivery of aerosols in a model of neonatal ventilation using a conventional and novel electronic micropump nebulizer. Aerosol deposition studies with 99mTc diethylenetriamine pentaacetate (99mTc-DTPA) were performed in four macaques (2.6 kg) that were ventilated through a 3.0-mm endotracheal tube (with neonatal settings (peak inspiratory pressure 12-14 mbar, positive end-expiratory pressure 2 mbar, I/E ratio 1/2, respiratory rate 40/min), comparing a jet-nebulizer MistyNeb (3-mL charge, 4.8 microm), an electronic micropump nebulizer operating continuously [Aeroneb Professional Nebulizer (APN-C); 0.5-mL charge, 4.6 microm], and another synchronized with inspiration [Aeroneb Professional Nebulizer Synchronized (APN-S); 0.5-mL charge, 2.8 microm]. The amount of radioactivity deposited into lungs and connections and remaining in the nebulizer was measured by a gamma counter. Despite similar amounts of 99mTc-DTPA in the respiratory circuit with all nebulizers, both APN-S and APN-C delivered more drug to the lungs than MistyNeb (14.0, 12.6, and 0.5% in terms of percentage of nebulizer charge, respectively; p = 0.006). Duration of delivery was shorter with APN-C than with the two other nebulizers (2 versus 6 and 10 min for the APN-S and the MistyNeb, respectively; p < 0.001). Electronic micropump nebulizers are more efficient to administer aerosols in an animal model of ventilated neonates. Availability of Aerogen's electronic micropump nebulizers offers new opportunities to study clinical efficacy and risks of aerosol therapy in ventilated neonates.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…