• Resp Care · Jun 2002

    Clinical validation of a continuous intravascular neonatal blood gas sensor introduced through an umbilical artery catheter.

    • Patricia A Meyers, Catherine Worwa, Robert Trusty, and Mark C Mammel.
    • Infant Pulmonary Research Center, Children's Hospital - St Paul, St Paul, Minnesota 55102, USA. pat.meyers@childrenshc.org
    • Resp Care. 2002 Jun 1; 47 (6): 682-7.

    IntroductionArterial blood gas (ABG) values are a necessary diagnostic measurement in the management of critically ill neonates. We hypothesized that a fiberoptic intravascular blood gas sensor, adapted for use through an umbilical artery catheter, would produce blood gas results with clinically acceptable bias and precision, in comparison to laboratory values, but with no blood loss.MethodsWe evaluated a fiberoptic intravascular blood gas sensor (Neotrend) in 23 consecutive neonates suffering respiratory failure. The sensor was inserted into the descending aorta via a 4.0 or 4.5 French umbilical artery catheter and extended 20 mm beyond the catheter tip. Arterial blood samples were drawn as clinically indicated and analyzed using a standard laboratory analyzer. Sensor measurements were recorded at the time of arterial blood sampling. Additionally, we recorded and evaluated data related to umbilical artery catheter placement (low position [L3-L4] vs high position [T8-T10]), duration of sensor functioning and use, and sensor bias and precision compared to the laboratory analyzer (using Bland-Altman technique and linear regression analysis of pH, P(aCO2), and P(aO2)).ResultsDuration of sensor use ranged from 1 to 304 hours (3-304 h in high position and 1-91 h in low position). Nine sensors were used for > 72 h (1 in low position and 8 in high position). Nine sensors were placed in low position, with a placement success rate of 56%. Eighteen sensors were placed in high position, with a placement success rate of 89%. The sensor values for pH, P(aCO2), and P(aO2) were strongly correlated (p < 0.0001) with the laboratory-determined values. Bias and precision for all values met standards for discrete analyzers for laboratory use.ConclusionsThe Neotrend device was accurate and reliable in the neonatal setting, allowing blood gas assessment with no iatrogenic blood loss. Catheter placement in high position may increase the likelihood of successful sensor placement and sensor duration of function.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.