• Clin Neurol Neurosurg · Feb 2016

    The diagnostic performance of ultrasonographic optic nerve sheath diameter and color Doppler indices of the ophthalmic arteries in detecting elevated intracranial pressure.

    • Mohammad Kazem Tarzamni, Babak Derakhshan, Ali Meshkini, Hamid Merat, Daniel Fadaei Fouladi, Samira Mostafazadeh, and Amir Rezakhah.
    • Department of Radiology, Imam Reza Teaching Hospital, Tabriz University of Medical Sciences, Tabriz, Iran.
    • Clin Neurol Neurosurg. 2016 Feb 1; 141: 82-8.

    ObjectivesTo assess the diagnostic accuracy of ultrasonographic optic nerve sheath diameter (ONSD) measurement and color Doppler indices of the ophthalmic arteries in detecting elevated intracranial pressure (ICP).Patients And MethodsA total 60 patients with (cases, n=30) and without (controls, n=30) acute clinical and computed tomographic findings of elevated ICP due to intracranial mass/hemorrhage were recruited from a teaching hospital. The mean binocular and maximum ultrasonographic ONSDs, as well as the mean binocular Doppler ultrasound waveform indices of the ophthalmic arteries including pulsatility index (PI), resistive index (RI), end-systolic velocity (ESV), peak systolic velocity (PSV) and end-diastolic velocity (EDV) were compared between the two groups.ResultsCompared to controls, the case group had significantly higher mean binocular ONSD (5.48 ± 0.52 mm vs. 4.09 ± 0.22 mm, p<0.001), maximum ONSD (5.63 ± 0.55 mm vs. 4.16 ± 0.23 mm, p<0.001), mean PI (1.53 ± 0.16 vs. 1.45 ± 0.20, p=0.01), and mean RI (0.76 ± 0.07 vs. 0.73 ± 0.04, p=0.01). The mean EDV, in contrast, was significantly higher in controls (8.55 ± 3.09 m/s vs. 7.17 ± 2.61 m/s, p=0.01). The two groups were comparable for the mean PSV (30.73 ± 7.93 m/s in cases vs. 32.27 ± 10.39 m/s in controls, p=0.36). Among the mentioned variables, the mean binocular ONSD was the most accurate parameter in detecting elevated ICP (sensitivity and specificity of 100%, cut-off point=4.53 mm). The Doppler indices were only moderately accurate (sensitivity: 56.7-60%, specificity: 63.3-76.7%).ConclusionWhile the ultrasonographic mean binocular ONSD (>4.53 mm) was completely accurate in detecting elevated ICP, color Doppler indices of the ophthalmic arteries were of limited value.Copyright © 2015 Elsevier B.V. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.