Comparative Study
In vitro comparison of central venous catheters for aspiration of venous air embolism: effect of catheter type, catheter tip position, and cardiac inclination.
- P G Hanna, N Gravenstein, and A G Pashayan.
- Department of Anesthesiology, University of Florida College of Medicine, Gainesville.
- J Clin Anesth. 1991 Jul 1; 3 (4): 290-4.
Study ObjectiveTo test the relative efficiency of balloon-tipped and plain catheters for aspiration of venous air embolism.DesignThe following four single-lumen central venous catheters were studied in a silastic model of the right atrium, tricuspid valve, and vena cavae: (1) the 16-gauge single-orifice catheter; (2) the 14-gauge Bunegin-Albin multiorifice catheter; (3) the 7-Fr pulmonary angiography catheter with balloon distal to orifices; (4) the 7-Fr pulmonary angiography catheter with balloon proximal to orifices. A 10% glycerol-water solution was circulated at 3.7 to 4.0 L/min. Catheter tips were positioned at 1 cm increments from -3 to +3 cm around the superior vena cava-right atrial junction with cardiac inclinations of 65 degrees and 80 degrees. Air (10 ml) was infused over 30 seconds; aspiration from the test catheter began 5 seconds later at 40 ml/min for 75 seconds. The balloon catheters were evaluated with the balloons inflated and deflated.SettingExperimental laboratory of a university-affiliated hospital.Measurements And Main ResultsAmounts of air aspirated were compared by analysis of variance and Tukey's multiple comparison, p less than 0.05, for all combinations. The 16-gauge single-orifice catheter tested best at a 65 degrees cardiac inclination with 86% of the venous air embolism recovered, while the 14-gauge Bunegin-Albin multiorifice catheter tested best at an 80 degrees cardiac inclination with 62% of the venous air embolism recovered. Both catheters functioned most efficiently at or above the superior vena cava-right atrial junction.ConclusionsThis study demonstrated that efficacy of air recovery depends on catheter type, catheter tip position, and cardiac inclination. No benefit was derived from positioning the catheter tip inside the atrium or from using balloon-tipped catheters.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.