• J Biomech Eng · Feb 2009

    The effect of screw pullout rate on screw purchase in synthetic cancellous bone.

    • Rad Zdero and Emil H Schemitsch.
    • Martin Orthopaedic Biomechanics Laboratory, St. Michael's Hospital, Shuter Wing (Room 5-066), 30 Bond Street, Toronto, ON, M5B 1W8, Canada. zderor@smh.toronto.on.ca
    • J Biomech Eng. 2009 Feb 1; 131 (2): 024501.

    AbstractClinically, orthopaedic fracture fixation constructs are mounted using screws inserted into cancellous bone, while biomechanical studies are increasingly using commercially available synthetic bones. The goal of this study was to examine the effect of screw pullout rate on cancellous bone screw purchase strength in synthetic cancellous bone. Sixty synthetic cancellous bone cubes (40x40x40 mm(3)) each had one orthopaedic cancellous bone screw (major diameter=6.5 mm) inserted to a depth of 30 mm. Screws were extracted to obtain outcome measures of failure force, failure shear stress, failure energy, failure displacement, resistance force, and removal energy. The ten test groups (n=6 cubes per group) had screws extracted at pullout rates of 1 mmmin, 2.5 mmmin, 5 mmmin, 7.5 mmmin, 10 mmmin, 20 mmmin, 30 mmmin, 40 mmmin, 50 mmmin, and 60 mmmin. The aggregate average results for failure force, failure stress, failure energy, failure displacement, resistance force, and postfailure removal energy for combined pullout rates were, respectively, 984.8+/-63.9 N, 3.5+/-0.2 MPa, 298.3+/-41.7 J, 0.53+/-0.08 mm, 453.8+/-19.6 N, and 5420.1+/-489.7 J. Most statistical differences (40 of 47) involved either the 5 mmmin or the 60 mmmin rates being compared to other rates. Failure force, failure stress, and resistance force increased and were highly linearly correlated with pullout rate (R(2)=0.78, 0.76, and 0.74, respectively). Failure energy, failure displacement, and removal energy were relatively unchanged over the pullout range tested, yielding low correlation coefficients (R(2)<0.05). Failure force, failure stress, and resistance force were affected by bone screw pullout rate in synthetic cancellous bone, while failure energy, failure displacement, and removal energy remained unchanged. This is the first study to perform an extensive investigation of cancellous bone screw pullout rate in synthetic cancellous bone.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.