• Acta radiologica · Jan 2015

    Comparative Study

    Standardized cine-loop documentation in abdominal ultrasound facilitates offline image interpretation.

    • Johann Baptist Dormagen, Mario Gaarder, and Anders Drolsum.
    • Department of Radiology, Oslo University Hospital, Ullevål, Oslo, Norway johannd@medisin.uio.no.
    • Acta Radiol. 2015 Jan 1; 56 (1): 3-9.

    BackgroundOne of the main disadvantages of conventional ultrasound is its operator dependency, which might impede the reproducibility of the sonographic findings. A new approach with cine-loops and standardized scan protocols can overcome this drawback.PurposeTo compare abdominal ultrasound findings of immediate bedside reading by performing radiologist with offline reading by a non-performing radiologist, using standardized cine-loop sequences.Material And MethodsOver a 6-month period, three radiologists performed 140 dynamic ultrasound organ-based examinations in 43 consecutive outpatients. Examination protocols were standardized and included predefined probe position and sequences of short cine-loops of the liver, gallbladder, pancreas, kidneys, and urine bladder, covering the organs completely in two planes. After bedside examinations, the studies were reviewed and read out immediately by the performing radiologist. Image quality was registered from 1 (no diagnostic value) to 5 (excellent cine-loop quality). Offline reading was performed blinded by a radiologist who had not performed the examination. Bedside and offline reading were compared with each other and with consensus results.ResultsIn 140 examinations, consensus reading revealed 21 cases with renal disorders, 17 cases with liver and bile pathology, and four cases with bladder pathology. Overall inter-observer agreement was 0.73 (95% CI 0.61-0.91), with lowest agreement for findings of the urine bladder (0.36) and highest agreement in liver examinations (0.90). Disagreements between the two readings were seen in nine kidneys, three bladder examinations, one pancreas and bile system examinations each, and in one liver, giving a total number of mismatches of 11%. Nearly all cases of mismatch were of minor clinical significance. The median image quality was 3 (range, 2-5) with most examinations deemed a quality of 3. Compared to consensus reading, overall accuracy was 96% for bedside reading and 94% for offline reading.ConclusionStandardized cine-loop documentation enables accurate offline reading in abdominal ultrasound and shows high agreement with immediate bedside reading.© The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.