• J Clin Anesth · May 1997

    Randomized Controlled Trial Comparative Study Clinical Trial

    Pulse oximeter performance during desaturation and resaturation: a comparison of seven models.

    • N S Trivedi, A F Ghouri, E Lai, N K Shah, and S J Barker.
    • Department of Anesthesiology, University of California at Irvine, Orange 92668, USA.
    • J Clin Anesth. 1997 May 1; 9 (3): 184-8.

    Study ObjectiveTo compare pulse oximeter performance during induced hypoxemia.DesignProspective investigation in human volunteers.SettingLaboratory facility at a university medical center.Patients8 unanesthetized, healthy ASA physical status I volunteers.InterventionsWe evaluated the accuracy and response times of seven popular pulse oximeters during induced hypoxemia. Arterial blood fractional oxygen saturation (SaO2) measurements were performed simultaneously and considered a gold standard.Measurements And Main ResultsAll oximeters were accurate (+/-2%) while subjects were breathing room air. During maximal hypoxemia (induced by breathing a FIO2 = 10% in nitrogen), large differences were noted between oxygen saturation as measured by pulse oximetry (SpO2) and SaO2 values, with pulse oximeters consistently underreporting SpO2 when actual SaO2 values were 75% or less. The Ohmeda 3740 (Ohmeda, Boulder, CO) using an ear probe was the first to detect desaturation (change in SpO2 > 3%) in 4 of 8 subjects (p < 0.05), and the Nellcor N200 reflectance oximeter (Nellcor, Inc., Pleasanton, CA) was first in 3 of 8 subjects (p < 0.05). During resaturation (after administering 100% oxygen), the Novametrix Oxypleth (Novametrix, Wallingford, CT) was significantly faster than other oximeters (p < 0.05) to return to baseline (SpO2 = 98%).ConclusionMost models of oximeters tested performed well when hemoglobin oxygen saturation was high, but all were inaccurate when SaO2 was approximately 75%. During induced hypoxemia, there were significant differences in the response times of oximeters tested, with no model demonstrably superior to others in all measures of performance.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…