BMC medical imaging · Jan 2008
Review Meta AnalysisMultidetector computed tomography angiography for assessment of in-stent restenosis: meta-analysis of diagnostic performance.
- Piet K Vanhoenacker, Isabel Decramer, Olivier Bladt, Giovanna Sarno, Erik Van Hul, William Wijns, and Ben A Dwamena.
- Department of Radiology and Imaging, OLV Ziekenhuis, Aalst, Belgium. piet@vanhoenacker.be
- BMC Med Imaging. 2008 Jan 1; 8: 14.
BackgroundMulti-detector computed tomography angiography (MDCTA)of the coronary arteries after stenting has been evaluated in multiple studies.The purpose of this study was to perform a structured review and meta-analysis of the diagnostic performance of MDCTA for the detection of in-stent restenosis in the coronary arteries.MethodsA Pubmed and manual search of the literature on in-stent restenosis (ISR) detected on MDCTA compared with conventional coronary angiography (CA) was performed. Bivariate summary receiver operating curve (SROC) analysis, with calculation of summary estimates was done on a stent and patient basis. In addition, the influence of study characteristics on diagnostic performance and number of non-assessable segments (NAP) was investigated with logistic meta-regression.ResultsFourteen studies were included. On a stent basis, Pooled sensitivity and specificity were 0.82(0.72-0.89) and 0.91 (0.83-0.96). Pooled negative likelihood ratio and positive likelihood ratio were 0.20 (0.13-0.32) and 9.34 (4.68-18.62) respectively. The exclusion of non-assessable stents and the strut thickness of the stents had an influence on the diagnostic performance. The proportion of non-assessable stents was influenced by the number of detectors, stent diameter, strut thickness and the use of an edge-enhancing kernel.ConclusionThe sensitivity of MDTCA for the detection of in-stent stenosis is insufficient to use this test to select patients for further invasive testing as with this strategy around 20% of the patients with in-stent stenosis would be missed. Further improvement of scanner technology is needed before it can be recommended as a triage instrument in practice. In addition, the number of non-assessable stents is also high.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.