• BMC medical imaging · Jan 2008

    Review Meta Analysis

    Multidetector computed tomography angiography for assessment of in-stent restenosis: meta-analysis of diagnostic performance.

    • Piet K Vanhoenacker, Isabel Decramer, Olivier Bladt, Giovanna Sarno, Erik Van Hul, William Wijns, and Ben A Dwamena.
    • Department of Radiology and Imaging, OLV Ziekenhuis, Aalst, Belgium. piet@vanhoenacker.be
    • BMC Med Imaging. 2008 Jan 1; 8: 14.

    BackgroundMulti-detector computed tomography angiography (MDCTA)of the coronary arteries after stenting has been evaluated in multiple studies.The purpose of this study was to perform a structured review and meta-analysis of the diagnostic performance of MDCTA for the detection of in-stent restenosis in the coronary arteries.MethodsA Pubmed and manual search of the literature on in-stent restenosis (ISR) detected on MDCTA compared with conventional coronary angiography (CA) was performed. Bivariate summary receiver operating curve (SROC) analysis, with calculation of summary estimates was done on a stent and patient basis. In addition, the influence of study characteristics on diagnostic performance and number of non-assessable segments (NAP) was investigated with logistic meta-regression.ResultsFourteen studies were included. On a stent basis, Pooled sensitivity and specificity were 0.82(0.72-0.89) and 0.91 (0.83-0.96). Pooled negative likelihood ratio and positive likelihood ratio were 0.20 (0.13-0.32) and 9.34 (4.68-18.62) respectively. The exclusion of non-assessable stents and the strut thickness of the stents had an influence on the diagnostic performance. The proportion of non-assessable stents was influenced by the number of detectors, stent diameter, strut thickness and the use of an edge-enhancing kernel.ConclusionThe sensitivity of MDTCA for the detection of in-stent stenosis is insufficient to use this test to select patients for further invasive testing as with this strategy around 20% of the patients with in-stent stenosis would be missed. Further improvement of scanner technology is needed before it can be recommended as a triage instrument in practice. In addition, the number of non-assessable stents is also high.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…