Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi · Apr 2012
[Effects of novel angled cervical disc replacement on facet joint stress].
- Chuanyi Bai, Weijie Zhang, Wei Ling, Zhenxing Tian, Xiaoqian Dang, and Kunzheng Wang.
- The First Department of Orthopaedics, the Second Affiliated Hospital of Medical College, Xi'an Jiaotong University, Xi'an Shaanxi, 710004, P.R. China. baichuanyiys@sina.com
- Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2012 Apr 1; 26 (4): 390-5.
ObjectiveTo analyze the biomechanical changes of the adjacent cervical facet joints when the angled cervical prosthesis is replaced.MethodsA total of 400 northwestern people were involved, with an age of 40 years or older. The cervical vertebra lateral X-ray films were taken, and the cervical angles were measured by professional computer aided design software, then the cervical intervertebral disc prosthesis with 10 degree angle was designed. The finite element models of C4, 5 and C4-6 segments with intact cervical discs were developed; the C4, 5 disc was replaced by the cervical prosthesis with 0 degrees and 10 degrees angle respectively; and then all models were subjected to axial loading, flexion/extension, lateral bending, and torsion loading conditions; the stress effects on adjacent facet joints after replacement were observed by comparing with that of the intact model.ResultsThe cervical angles were (9.97 +/- 3.64) degrees in C3, 4, (9.95 +/- 4.34) degrees in C4, 5, (8.59 +/- 3.75) degrees in C5, 6, and (8.49 +/- 3.39) degrees in C6, 7, showing no significant difference between C3, 4 and C4, 5, C5, 6 and C6, 7 (P > 0.05) and showing significant differences between the other cervical angles (P < 0.05). When C4, 5 model was axially loaded, no significant difference in equivalent shearing stress were observed in intact, 0 degrees, and 10 degrees groups; at flexion/extension loading, the stress was biggest in intact group, and was smallest in 10 degrees group; at lateral bending, the stress got the high rank in intact group, and was minimum in 10 degrees group; at torsion loading, the stress state of 10 degrees group approached to the intact one condition. When C4-6 model was loaded, the facet joint stress of the replaced segment (C4, 5) decreased significantly at axial loading, flexion/extension, and lateral bending; while no obvious decrease was observed at torsion loading; the stress of the adjacent inferior disc (C5, 6) decreased significantly at axial loading and lateral bending condition, while less decrease was observed at torsion loading, no significant change at flexion/extension condition, it approached to that of the intact one.ConclusionThe finite element analysis reveals that the biomechanical properties of 10 degrees designed prosthesis is approximate to that of the intact cervical disc, thus the 10 degrees designed prosthesis can meet the requirements of biomechanical function reconstruction of the cervical spine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.