-
Osteoarthr. Cartil. · Jul 2009
Randomized Controlled Trial Multicenter StudyReproducibility and sensitivity to change of a new method of computer measurement of joint space width in hip osteoarthritis. Performance of three radiographic views obtained at a 3-year interval.
- T Conrozier, K Brandt, M Piperno, P Mathieu, F Merle-Vincent, and E Vignon.
- Department of Rheumatology, Lyon Sud University Hospital, Pierre-Bénite, France. thierry.conrozier@chu-lyon.fr
- Osteoarthr. Cartil. 2009 Jul 1; 17 (7): 864-70.
BackgroundMeasurement of radiographic joint space width (JSW) and of joint space narrowing (JSN) is the currently recommended method for assessment of anatomical severity and structural progression of osteoarthritis (OA), respectively. A standard radiographic view of the pelvis is commonly used for measurement of hip OA but other views are available.ObjectivesTo evaluate the inter-intra reader reproducibility and the sensitivity to change of a new automated method of measurement of the hip JSW and to assess which radiographic view [pelvis anteroposterior (AP) view, hip AP view, hip oblique view] provides the greatest accuracy for JSW and JSN measurements.Material And MethodsAn AP pelvis radiograph, an AP radiograph centered on the target hip (AP hip) and an oblique view were performed at baseline (M0) and 3 years later (M36) in 50 hip OA patients. Two readers, blinded to each other's results and time sequence, measured twice, at a minimum 15 day interval, the six radiographs of each patient, using a novel version of a previously validated software program whose edge-based algorithm automatically detects the joint space contours. Inter-observer cross-sectional (M0+M36) and longitudinal (M0-M36) reproducibility of JSW measurement was assessed by the intra-class correlation coefficient (ICC) and the Bland-Altman method. Sensitivity to change was estimated by the standardized response mean (SRM). An ANOVA was used to analyze differences related to the observer and the view.ResultsIntra-observer reproducibility: For JSW measurement, the ICC value, for observers 1 and 2 respectively, were 0.92 and 0.83 for the pelvic view, 0.96 and 0.88 for the hip AP view, and 0.90 and 0.86 for the oblique view. For JSN, ICC was 0.94 and 0.82 for the pelvic view, 0.97 and 0.78 for the hip AP view, and 0.95 and 0.86 for the oblique view. Inter-observer reproducibility: For JSW measurement, ICC was 0.87 for the pelvic view, 0.98 for the hip AP view, and 0.87 for the oblique view. The mean inter-observer difference (SD) was 0.0 (0.31), -0.01 (0.15) and -0.04 (0.4)mm for pelvic, AP and oblique views respectively. For JSN, ICC was 0.91 for the pelvic view, 0.93 for the hip AP view, and 0.90 for the oblique view. Sensitivity to change: SRM values were 0.61 (observer 1) and 0.65 (observer 2) for the pelvic view, 0.68 and 0.75, respectively, for the hip AP view, 0.64 and 0.66, respectively, for the oblique view. JSN did not vary significantly with the observer and the view. In 27% of cases intervention by the observer was necessary to correct the computer's identification of the acetabular edge in the area of interest.ConclusionComputer measurement of the radiographic hip joint space provided good intra- and inter-observer reproducibility and good sensitivity to change. However, it was necessary for the observer to intervene frequently to select the area of interest and adjust detection of the bone edge. The hip AP view performed better than the pelvis and oblique views, but not significantly so.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.