- L Seller, K Mullahoo, S Liben, and L C Lands.
- Division of Respiratory Medicine, Montreal Children's Hospital, McGill University Health Center, 2300 Tupper, Montreal, Quebec, Canada H3H 1P3.
- Resp Care. 2001 Mar 1; 46 (3): 263-6.
AbstractWe report the successful weaning and extubation of an infant from a SensorMedics 3100A high-frequency oscillator without returning to conventional ventilation. A 7-week-old term infant with respiratory syncytial virus bronchiolitis complicated by cystic pulmonary lesions repeatedly failed attempts to return to conventional ventilation from high-frequency oscillatory ventilation (HFOV) for weaning, because of recurrent pneumothoraces. A computed tomography of the chest revealed multiple well defined cysts of various sizes involving both lungs. Therefore, weaning to extubation from HFOV was proposed as a way of preventing further air leak. The weaning strategy consisted of a technique we refer to as "sprinting." Using this method, the patient was successfully extubated directly from HFOV, with no complications. A follow-up computed tomography of the chest showed marked improvement in the size of the cystic lesions. The patient was discharged home with no need for home oxygen therapy.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.