• J Clin Monit Comput · Feb 2018

    Beat-by-beat assessment of cardiac afterload using descending aortic velocity-pressure loop during general anesthesia: a pilot study.

    • Fabrice Vallée, Arthur Le Gall, Jona Joachim, Olivier Passouant, Joaquim Matéo, Arnaud Mari, Sandrine Millasseau, Alexandre Mebazaa, and Etienne Gayat.
    • Department of Anesthesiology and Critical Care, Anesthesiology - Intensive care - SMUR Department, St-Louis-Lariboisière-Fernand Widal University Hospitals, Assistance Publique-Hôpitaux de Paris, Paris, France. vallee.fabrice@gmail.com.
    • J Clin Monit Comput. 2018 Feb 1; 32 (1): 23-32.

    IntroductionContinuous cardiac afterload evaluation could represent a useful tool during general anesthesia (GA) to titrate vasopressor effect. Using beat to beat descending aortic pressure(P)/flow velocity(U) loop obtained from esophageal Doppler and femoral pressure signals might allow to track afterload changes. Methods We defined three angles characterizing the PU loop (alpha, beta and Global After-Load Angle (GALA)). Augmentation index (AIx) and total arterial compliance (Ctot) were measured via radial tonometry. Peripheral Vascular Resistances (PVR) were also calculated. Twenty patients were recruited and classified into low and high cardiovascular (CV) risk group. Vasopressors were administered, when baseline mean arterial pressure (MAP) fell by 20%. Results We studied 118 pairs of pre/post bolus measurements. At baseline, patients in the lower CV risk group had higher cardiac output (6.1 ± 1.7 vs 4.2 ± 0.6 L min; p = 0.005), higher Ctot (2.7 ± 1.0 vs 2.0 ± 0.4 ml/mmHg, p = 0.033), lower AIx and PVR (13 ± 10 vs 32 ± 11% and 1011 ± 318 vs 1390 ± 327 dyn s/cm5; p < 0.001 and p = 0.016, respectively) and lower GALA (41 ± 15 vs 68 ± 6°; p < 0.001). GALA was the only PU Loop parameter associated with Ctot, AIx and PVR. After vasopressors, MAP increase was associated with a decrease in Ctot, an increase in AIx and PVR and an increase in alpha, beta and GALA (p < 0.001 for all). Changes in GALA and Ctot after vasopressors were strongly associated (p = 0.004). Conclusions PU Loop assessment from routine invasive hemodynamic optimization management during GA and especially GALA parameter could monitor cardiac afterload continuously in anesthetized patients, and may help clinicians to titrate vasopressor therapy.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…