• World Neurosurg · May 2017

    Review Case Reports

    Balloon Angioplasty for in-stent restenosis resulting in carotid stent fracture with literature review of stent-in-stent technique as a viable therapeutic option.

    • Abdul-Haseeb Naeem, Ghaya Al-Rumaihi, Amirpouyan Namavarian, Manas Sharma, and Melfort Boulton.
    • Division of Neurosurgery, Department of Clinical Neurological Sciences, London Health Sciences Centre, London, Ontario, Canada. Electronic address: abdul.naeem@lhsc.on.ca.
    • World Neurosurg. 2017 May 1; 101: 818.e1-818.e6.

    BackgroundCarotid stent fractures are rare, and multiple etiologies have been proposed to explain their occurrence. We describe a patient with an internal carotid artery (ICA) stent who developed in-stent restenosis. We performed balloon angioplasty to address in-stent restenosis, but he developed a carotid stent fracture after the procedure. To our knowledge, balloon angioplasty has not been reported to cause stent fractures.Case DescriptionA 72-year-old man underwent stent placement for symptomatic left ICA stenosis with residual stenosis of 55% after stent placement. He presented with transient ischemic attacks 2 months later, and work-up revealed in-stent restenosis of the left ICA. Given prior complete occlusion of right ICA and right vertebral artery and narrowing of left vertebral artery ostium, satisfactory balloon (5 × 40 mm) angioplasty was carried out. After balloon angioplasty, x-ray showed a new stent fracture, which was initially missed on immediate postoperative imaging. He presented 9 months later with symptoms of compromised cerebral perfusion. Work-up revealed the previously missed stent fracture causing blood flow changes. Peak systolic velocity in the left ICA was 383 cm/second. He underwent left ICA repeat stent placement via a stent-in-stent technique for symptomatic severe left ICA stenosis of 70% with 40% residual stenosis after new stent deployment.ConclusionsBalloon angioplasty to address in-stent restenosis can secondarily cause stent fractures. We provide evidence of successful management of stent fracture with recurrent in-stent stenosis by repeat stent placement via a stent-in-stent technique.Copyright © 2017 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…